Product characteristics
Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1
Probe length L [mm] 264
Application
System gold-plated contacts
Media hydrous coolants; mineral oils (dielectric constant < 3); water; media similar to water
Dielectric constant of the medium > 2
Cannot be used for media with separation layers (oil / water; oil / metal layer); acids and alkalis
Medium temperature [°C] 0...65; (for water and hydrous media with temperatures > 35 °C install the unit into a climatic tube)
Tank pressure [bar] 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 80
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 3
Measuring principle capacitive
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal
Electrical design PNP
Number of digital outputs 1
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 200
Number of analog outputs 1
Analog current output [mA] 4...20
Max. load [Ω] 500
Analog voltage output [V] 0...10
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Probe length L [mm] 264
Active range A [mm] 195
Inactive range I1 / I2 [mm] 53 / 15
Setting range
Set point SP [mm] 25...205
Reset point rP [mm] 20...200
In steps of [mm] 5
Hysteresis [mm] 5
Accuracy / deviations
Measuring error [% of the final value] ± 5
Repeatability ± 2
Software / programming
Adjustment of the switch point Programming button
Operating conditions
Ambient temperature [°C] 0...60
Storage temperature [°C] -25...80
Protection IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 500 V / 1 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance
12 g
Vibration resistance
2.5 g
Mechanical data
Dimensions [mm] Ø 16
Material EPDM/X; FKM; brass Optalloy-plated; NBR; PA; PBT; PC; PP
Materials (wetted parts) PP
Displays / operating elements
Display
Switching status LED, red
Function display 7-segment LED display
Measured values 7-segment LED display
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated