- PM / PY flush mount pressure transmitters
- Select products
- PM17 - 1" sensor connection
Transmitters with 1" connection
Part No. | Factory default range (psi) |
Full range (psi) |
IO-Link range (psi) |
IO-Link resolution (psi) |
Overload / burst pressure (psi) |
|
---|---|---|---|---|---|---|
PM1789 | 0...40 inH2O | -2...40 inH2O | -4...42.15 inH2O | 0.008 inH2O | 58 / 435 | |
PM1708 | 0...100 inH2O | -5...100 inH2O | -10...105.4 inH2O | 0.02 inH2O | 84 / 435 | |
PM1718 | 0...160 inH2O | -20...160 inH2O | -28...169 inH2O | 0.04 inH2O | 116 / 435 | |
PM1709 | -14.5...14.5 | -14.5...14.5 | -14.5...15.95 | 0.008 | 145 / 435 | |
PM1707 | 0...14.5 | -0.73...14.5 | -1.45...15.23 | 0.003 | 145 / 435 | |
PM1717 | 0...23.21 | -1.45...23.21 | -2.61...24.37 | 0.005 | 215 / 580 | |
PM1706 | 0...36.26 | -1.82...36.26 | -3.625...38.07 | 0.008 | 290 / 725 | |
PM1705 | 0...58 | -14.5...58 | -14.5...60.9 | 0.015 | 435 / 1450 | |
PM1715 | 0...87 | -14.5...87 | -14.5...91.4 | 0.030 | 435 / 1450 | |
PM1704 | 0...145 | -14.5...145 | -14.5...152.3 | 0.030 | 725 / 2175 | |
PM1714 | 0...232 | -14.5...232 | -14.5...243.7 | 0.076 | 1085 / 3625 | |
PM1703 | 0...362.6 | -14.5...362.6 | -14.5...381 | 0.076 | 1450 / 5075 | |
PM1602* | -14.5...1450 | -14.5...1450 | -14.5...1523 | 0.304 | 2900 / 9425 |
* PM1602 has a different process connection from the PM17 transmitters. Please consult the datasheet for appropriate fittings.