Sensor family | Flow rate | Line size | Accuracy | Medium temperature | Points to consider |
---|---|---|---|---|---|
SU8020 | 1...240 lpm | G1" | ~ ±2% | -4…212 °F -20…100 °C |
|
SU8021 | 1...240 lpm or 0.26...63.4 gpm |
G1" | |||
SU8621 | 1...240 lpm or 0.26...63.4 gpm |
1"NPT | |||
SU2020 | 5...1,000 lpm | G2" | |||
SU2021 | 5...1,000 lpm or 1.32...264.18 gpm |
G2" | |||
SU2621 | 5...1,000 lpm or 1.32...264.18 gpm |
2" NPT |
Other solutions for water-based media...
Sensor family | Flow rate | Line size | Medium temperature | Accuracy | Points to consider |
---|---|---|---|---|---|
![]() SM |
5 ml/min (0.08 gpm)…160 gpm |
1/4"…2" | 14…158 °F -4...194 °F (units with TFT display) |
~ ±1% | • Conductivity ≥ 20 µS/cm • Totalizer function • Pressure ≤ 232 psi • Versions with TFT display have selectable units of measure |
![]() SV |
0.26…26.4 gpm | 1/2"…3/4" | 14…194 °F -10…90 °C |
~ ±2% | • Display flow and temperature • Water content ≥ 95% • Pressure rating ≤ 174 psi • Long straight pipe required |
![]() SA |
0.1…6150 gpm | 1/2"…16" | -4…212 °F -20…100 °C Higher upon request |
~ ±10% | • Pressure ≤ 1450 psi • Avoid rapid medium temperature changes |
![]() SB |
0.1…50 gpm | 3/4"…1-1/2" | 14…212 °F -10…100 °C |
~ ±5% | • No straight pipe runs required • Response time ≤ 10 msec • Pressure ≤ 580 psi |
![]() SI |
3…100 cm/s | 1/8"…8" | -13…176 °F -25…80 °C |
~ ±10% | • Pressure < 4350 psi • Sanitary versions available • Avoid rapid medium temperature changes |