The key to a successful implementation of any solution is a firm understanding of all requirements. PDS is no different. This section provides all details required to ensure successful implementation of PDS. This includes:
Following these steps will ensure a successful PDS implementation.
Inclination
Mounting height
The PDS is integrated in the O3D Camera. This camera requires a 24V DC power supply and communicates via Ethernet. The wiring of both interfaces is shown in the following image:
Connector: 1 x M12 Electrical connection: Process connection |
Connector: 1 x M12 Electrical connection: Ethernet |
---|---|
1. U+ | 1. TD+ |
2. Trigger input | 2. RD+ |
3. GND | 3. TD- |
4. Switching output 1 ready | 4. RD- |
5. Switching output 1 cascading |
Note: The camera requires 2.4 A peak current during image capture.
The PDS is designed to detect pallets with two pallet pockets. A distinction is made between "block" and "stringer" pallets.
Wood, block |
Wood, stringer |
Plywood, stringer |
Double-sided |
Reversible |
2-way |
GMA 4-way |
Single-face, stringer |
CHEP |
PECO |
Plastic |
Nestable, plastic |
IGPS |