You probably do not come from: Ireland. If necessary, change to: United States
Service hotline +3531 461 3200
  1. Products
  2. Sensors
  3. Ultrasonic sensors
  4. All ultrasonic sensors
  5. UIT302

full-metal ultrasonic sensor

UIT302

UID02500E2KG/IO-Link/US

full-metal ultrasonic sensor

UIT302

UID02500E2KG/IO-Link/US

  • Continuous level and object detection for harsh environments
  • Resistant to aggressive media
  • Long range
  • Programmable switching output with IO-Link and analogue output
  • ce
  • ukca
  • iolink
Product characteristics
Electrical design PNP/NPN; (parameterisable)
Output function normally open / normally closed; (parameterisable)
Sensing range [mm] 250...2500; (Target: 400 x 400 mm)
Communication interface IO-Link
Housing threaded type
Dimensions [mm] M30 x 1.5 / L = 103
Electrical data
Operating voltage [V] 10...30 DC
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 0.5
Converter frequency [kHz] 112
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP/NPN; (parameterisable)
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.2
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 1
Number of analogue outputs 1
Analogue voltage output [V] 0...10
Min. load resistance [Ω] 3000
Short-circuit protection yes
Overload protection yes
Detection zone
Sensing range [mm] 250...2500; (Target: 400 x 400 mm)
Blind zone [mm] 250
Angle of aperture cylindrical [°] 12; (±2)
Max. deviation from the 90° angle sensor/object [°] ± 4
Accuracy / deviations
Temperature compensation yes
Hysteresis [%] < 3
Linearity error of analogue output [%] <3
Temperature drift ± 5 %; (of the final value of the measuring range)
Repeatability 1 %
Resolution [mm] 3
Notes on the accuracy / deviation The indicated values are reached after a warm-up time of min. 20 minutes
Response times
Response time [s] analogue output
Response time [ms] < 600
Software / programming
Parameter setting options hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel
SIO mode yes
Required master port type A
Min. process cycle time [ms] 3.2
IO-Link process data (cyclical)
function bit length
process value 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter
Supported DeviceIDs
Type of operation DeviceID
default 1390
Note
For further information please see the IODD PDF file under "Downloads"
Operating conditions
Ambient temperature [°C] -10...60
Storage temperature [°C] -15...65
Protection IP 65; IP 67; IP 68; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 3 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 3 V
EN 55011 Class A
Vibration resistance
EN 60068-2-6 Fc (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
MTTF [years] 108
Mechanical data
Weight [g] 259.6
Housing threaded type
Dimensions [mm] M30 x 1.5 / L = 103
Thread designation M30 x 1.5
Materials stainless steel (1.4404 / 316L); LED window: TPU; potting: PUR
Tightening torque [Nm] 100
Displays / operating elements
Display
switching status 1 LED, yellow
Accessories
Items supplied
lock nuts: 2, stainless steel
damping plates: 2, EPDM
Remarks
Pack quantity 1 pcs.
Electrical connection - plug
Connection Connector: 1 x M12; coding: A
Diagrams and graphs
Standard sound beam
Medium sound beam
Narrow sound beam