Product characteristics |
Output function |
normally open / normally closed; (selectable) |
Sensing range [mm] |
15 |
Housing |
threaded type |
Dimensions [mm] |
M30 x 1.5 / L = 151 |
Electrical data |
Operating voltage [V] |
20...250 AC/DC |
Protection class |
II |
Reverse polarity protection |
no |
Outputs |
Output function |
normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V] |
8 |
Max. voltage drop switching output AC [V] |
10 |
Minimum load current [mA] |
5 |
Max. leakage current [mA] |
2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
Permanent current rating of switching output AC [mA] |
130; (250 (...40 °C) 250 (...50 °C); when used outside the hazardous area: 200 (...70 °C)) |
Permanent current rating of switching output DC [mA] |
130; (250 (...40 °C) 250 (...50 °C); when used outside the hazardous area: 200 (...70 °C)) |
Short-time current rating of switching output [mA] |
1500; (20ms / 0,5Hz) |
Switching frequency AC [Hz] |
25 |
Switching frequency DC [Hz] |
50 |
Short-circuit proof |
no |
Overload protection |
no |
Detection zone |
Sensing range [mm] |
15 |
Sensing range adjustable |
yes |
Factory setting sensing range [mm] |
15 |
Real sensing range Sr [mm] |
15 ± 10 % |
Accuracy / deviations |
Correction factor |
glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
Hysteresis [% of Sr] |
1...15 |
Switch point drift [% of Sr] |
-15...15 |
Operating conditions |
Ambient temperature [°C] |
-20...60 |
Note on ambient temperature |
when used outside the hazardous area: -25...70 °C |
|
Protection |
IP 54; (when used outside the hazardous area: IP 65) |
Increased immunity |
yes |
Tests / approvals |
ATEX marking |
II 3D Ex tD A22 IP54 T80°C X |
EMC |
|
MTTF [years] |
294 |
Mechanical data |
Weight [g] |
0.161 |
Housing |
threaded type |
Mounting |
non-flush mountable |
Dimensions [mm] |
M30 x 1.5 / L = 151 |
Thread designation |
M30 x 1.5 |
Materials |
PBT; PA |
Tightening torque for cable gland [Nm] |
2.7; (maximum: 3,5) |
Displays / operating elements |
Display |
switching status |
1 x LED, yellow |
|
Electrical connection |
Required protection |
miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
Accessories |
Accessories (supplied) |
lock nuts: 2 |
screwdriver: 1 |
|
Remarks |
Remarks |
Recommendation: Check the safe functioning of the unit after a short circuit. |
Special conditions for safe operation apply for use in hazardous areas. |
Observe the corresponding notes in the operating instructions (Ex protection related part). |
|
Notes |
discontinued article |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
terminals: ...2.5 mm²; Cable sheath: Ø 5.5...13 mm; Cable gland: M20 X 1.5 |