Product characteristics |
Output signal |
switching signal |
Measuring range |
0...400 bar |
0...5800 psi |
0...40 MPa |
|
Process connection |
threaded connection G 1/4 internal thread |
Application |
Medium temperature [°C] |
-25...80 |
Min. bursting pressure |
1000 bar |
14500 psi |
100 MPa |
|
Pressure rating |
|
Electrical data |
Operating voltage tolerance [%] |
5...10 |
Operating voltage [V] |
85...265 AC |
Nominal voltage AC [V] |
< 250 |
Current consumption [mA] |
< 10 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
II |
Reverse polarity protection |
no |
Power-on delay time [s] |
0.2 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1 |
Outputs |
Total number of outputs |
1 |
Output signal |
switching signal |
Electrical design |
Triac |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output AC [V] |
2 |
Permanent current rating of switching output AC [mA] |
250; ((...70 °C) 1000 (...60 °C) 1500 (...45 °C) 2500 (...20 °C)) |
Switching frequency AC [Hz] |
< 160 |
Short-circuit proof |
no |
Overload protection |
no |
Measuring/setting range |
Measuring range |
0...400 bar |
0...5800 psi |
0...40 MPa |
|
Set point SP |
4...400 bar |
60...5800 psi |
0.4...40 MPa |
|
Reset point rP |
2...398 bar |
30...5770 psi |
0.2...39.8 MPa |
|
In steps of |
|
Accuracy / deviations |
Switch point accuracy [% of the span] |
< ± 1,0 |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
Linearity deviation [% of the span] |
< ± 0,5 |
Hysteresis deviation [% of the span] |
< ± 0,1 |
Long-term stability [% of the span] |
< ± 0,1; (per year) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,2; (-25...80 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,3; (-25...80 °C) |
Response times |
Delay time programmable dS, dr [s] |
0, 0,2,...10, 11,...50 |
Damping for the switching output dAP [s] |
0...4 |
Software / programming |
Adjustment of the switch point |
programming button |
Parameter setting options |
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit |
Operating conditions |
Ambient temperature [°C] |
-25...80 |
Storage temperature [°C] |
-40...100 |
Protection |
IP 67 |
Tests / approvals |
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-6 HF conducted |
10 V |
|
Shock resistance |
DIN IEC 68-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN IEC 68-2-6 |
20 g (10...2000 Hz) |
|
MTTF [years] |
224.58 |
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data |
Weight [g] |
387 |
Materials |
FKM; PA; PBT; PC; stainless steel (1.4301 / 304) |
Materials (wetted parts) |
stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles |
100 million |
Process connection |
threaded connection G 1/4 internal thread |
Restrictor element integrated |
yes |
Displays / operating elements |
Display |
switching status |
LED, red |
function display |
7-segment LED display |
measured values |
7-segment LED display |
|
Display unit |
bar; psi; MPa |
Electrical connection |
Required protection |
miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting |
Remarks |
Remarks |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x 1/2" |