You probably do not come from: Hong Kong SAR China. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Photoelectric sensors
  4. All photoelectric sensors
  5. O6H700

Diffuse reflection sensor with background suppression

O6H700

O6HLFPKG

Diffuse reflection sensor with background suppression

O6H700

O6HLFPKG

  • Precise background suppression
  • Excellent price/performance ratio
  • Compact rectangular design
  • Reliable transmission of the distance as linearised process value via IO-Link
  • ce
  • ukca
  • cul
  • iolink
Product characteristics
Type of light red light
Laser protection class 1
Housing rectangular
Application
Special feature Background suppression
Function principle Diffuse reflection sensor
Electrical data
Operating voltage [V] 10...30 DC
Current consumption [mA] 16; (24 V)
Protection class III
Reverse polarity protection yes
Type of light red light
Wave length [nm] 650
Outputs
Electrical design PNP
Output function light-on/dark-on mode; (selectable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 1000
Short-circuit protection yes
Type of short-circuit protection pulsed
Detection zone
Range [mm] 1...100; (white paper 200 x 200 mm)
Range on white object (90 % remission) [mm] 1...100
Range on grey object (18 % remission) [mm] 8...100
Range on black object (6 % remission) [mm] 12...100
Range adjustable yes
Max. light spot diameter [mm] 2
Background suppression available yes
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Device Identification; Device Diagnosis; Teach Channel; Switching Channel; Process Data Variable
SIO mode yes
Required master port type A
Min. process cycle time [ms] 10
IO-Link process data (cyclical)
function bit length
process value 32
device status 4
binary switching information 1
IO-Link functions (acyclical) application specific tag; operating hours counter; switch-on cycle counter
Supported DeviceIDs
Type of operation DeviceID
default 526
Operating conditions
Ambient temperature [°C] -10...60
Protection IP 65; IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 1
Notes on laser protection
Caution: laser light
laser class: 1
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 594
Mechanical data
Weight [g] 60.7
Housing rectangular
Dimensions [mm] 35.4 x 13 x 21
Materials housing: ABS; PPSU; Sealing: EPDM
Lens material
PMMA
Lens alignment side lens
Tightening torque [Nm] 0.5; (screws)
Displays / operating elements
Display
switching status 1 x LED, yellow
operation 1 x LED, green
Remarks
Remarks
operating voltage "supply class 2" according to cULus
Pack quantity 1 pcs.
Electrical connection
Connection Cable: 2 m, PUR, black, Ø 3.7 mm; 3 x 0.25 mm²
Diagrams and graphs
a: sensor
b: object
c: background
x: distance sensor/object [mm]
y: min. distance object/background [mm]
x: distance sensor/object [mm]
y: min. distance object/background [mm]
1 = object black (6 % remission) , background white (90 % remission)
2 = object grey (18 % remission) , background white (90 % remission)
3 = object white (90 % remission) , background white (90 % remission)
Other data
Repeatability / precision: 6 σ
repeatability of the measured values
Abstand white (90 % remission) black (6 %...90 % remission)
20 mm 0.1 mm 0.5 mm
50 mm 0.2 mm 1.0 mm
100 mm 0.5 mm 2.0 mm
accuracy
Abstand white (90 % remission) black (6 %...90 % remission)
20 mm ± 0.6 mm ± 0.9 mm
50 mm ± 1.5 mm ± 2.0 mm
100 mm ± 3.0 mm ± 4.0 mm
The values apply at
Extraneous light on the object < 10 klx
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10
IO-Link - measuring mode