  • Winkelauflösung ermöglicht präzise Ausgabe der Positionskoordinaten
  • Reliable measurements even in precipitation, fog, dust and dirt
  • output of 3D point cloud
  • Operating modes can be set in accordance with the specific application
  • Intuitive set-up and visualisation of the measured data using the ifm Vision Assistant software

The application area of the device depends on the base frequency used and the country in which it is operated. You will find an overview in the operating instructions and here

  • ce
Product characteristics
Communication interface CAN
Housing rectangular
Dimensions [mm] 80 x 80 x 45
Application
Note on radio approval
The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”.
Electrical data
Operating voltage [V] 9...32 DC; (to SELV/PELV ; energy-limited circuits according to IEC/UL 61010-1 3rd ed. cl. 9.4)
Current consumption [mA] < 300; (mean value: 150 mA)
Power consumption [W] 9; (maximum)
Protection class III
Reverse polarity protection yes
Max. power-on delay time [ms] 1000
Operating frequency [GHz]
60...64
Average spectral density EIRP [dBm/MHz]
-15
Average transmitter power EIRP [dBm]
15
Detection zone
Range [m] 0.1...50; (referred to E23014)
Angle of aperture cylindrical [°]
horizontal 140
vertical 50
Note static objects in the range < 1 m are not stably detected in area mode
Measuring/setting range
Measuring range [m] 0.1...50; (see diagram:)
Sampling rate [Hz] 20
Software / programming
Parameter setting options via PC with ifm Vision Assistant
Interfaces
Communication interface CAN
Number of CAN interfaces 1
Transmission rate 250 (125...1000) kBaud
Protocol SAE J1939
Factory settings
Baud rate: 250
device address (ECU): 126
UDS interface: 1000 kBaud
Usage type parameter setting; data transmission
Note
Weitere Informationen entnehmen Sie dem Software Handbuch unter “Downloads"
Operating conditions
Ambient temperature [°C] -40...85
Storage temperature [°C] -40...85
Protection IP 65; IP 66; IP 67; IP 69K; (with mounted connectors or protective caps)
Tests / approvals
EMC
DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD
DIN EN 61000-4-3 HF radiated 10 V/m
DIN EN 61000-4-4 Burst 2 kV
DIN EN 61000-4-6 HF conducted 10 V
DIN EN 61000-6-2 immunity / industrial environments
EN 55032 emission Class A
Impact resistance
IEC 62262 IK06 (1J)
Vibration resistance
DIN EN 60068-2-6 Fc 10 g 10 frequency cycles, 1 octave/minute, in 3 axes
Shock resistance
DIN EN 60068-2-27 Ea 50 g 11 ms half-sine; 10 shocks each in every direction along the 3 coordinate axes
Continuous shock resistance
DIN EN 60068-2-29 Eb 40 g 6 ms half-sine; 4,000 shocks each in every direction along the 3 coordinate axes
Fast temperature change
DIN EN 60068-2-14 Na TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 30 s; 300 cycles
Salt spray test
DIN EN 60068-2-11 Ka 8 test cycles
Electrical protection
DIN EN 61010-2-201 electric shock / electrical supply only via SELV/PELV circuits
MTTF [years] 56
Mechanical data
Weight [g] 405.3
Housing rectangular
Mounting flush mountable
Dimensions [mm] 80 x 80 x 45
Materials housing: PA; radome: PEI; Sealing: HNBR
Displays / operating elements
Display
operation 1x LED, green
errors 1x LED, red
Remarks
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; coding: A
Diagrams and graphs
Detection zone
1: azimuth
2: elevation
conditions
Reflector: 4.3“ Trihedral Corner Reflector (SAJ043-S1)
RCS: 8 dBm²
distance: 5 m
operating frequency: 62 GHz
Other data
Operating mode standard Long range, high velocity
max. distance 0.1...20 m 0.25...30 m
distance resolution 100 mm 360 mm
horizontal angular resolution (azimuth ) 10 ° 10 °
distance accuracy ± 5 mm ± 15 mm
max. velocity ± 6 m/s ± 15 m/s
velocity resolution ± 0.25 m/s ± 0.38 m/s
speed accuracy ± 0.01 m/s ± 0.04 m/s
Sampling rate 20 Hz 20 Hz
distance referred to E23013
Resolution for the detection of two objects of the same size
accuracy for a strong, point-shaped target