You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Sensors
  3. Photoelectric sensors
  4. Measuring light grids
  5. OY5106

measuring light grid

OY5106

OYA1040-105-0-10-C-3-IO

measuring light grid

OY5106

OYA1040-105-0-10-C-3-IO

  • Simple object dimensioning in intralogistics without complex programming
  • High resolution for precise object detection
  • Ease of integration due to a standardised IO-Link interface
  • Selective evaluation of beams to determine the dimensions or distances between objects
  • ce
Product characteristics
Type of light infrared light
Electrical design PNP/NPN; (parameterisable)
Protection IP 65; IP 67
Electrical data
Operating voltage [V] 19.2...28.8 DC
Protection class III
Reverse polarity protection yes
Max. power-on delay time [ms] 300
Type of light infrared light
Wave length [nm] 880
Receiver
Current consumption [mA] 90
Transmitter
Current consumption [mA] 15
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1
Outputs
Electrical design PNP/NPN; (parameterisable)
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Max. current load per output [mA] 100
Switching frequency DC [Hz] 14
Short-circuit protection yes
Overload protection yes
Detection zone
Number of beams 105
Sensing field height [mm] 1040
Sensing field width (low light intensity) [m] 0...2
Sensing field width (high light intensity) [m] 1...10
Distance between beams [mm] 10
Software / programming
Parameter setting options hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel
SIO mode yes
Required master port type A
Min. process cycle time [ms] 10
IO-Link process data (cyclical)
function bit length
process value 80
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter
Supported DeviceIDs
Type of operation DeviceID
default 1401
Note
For further information please see the IODD PDF file under "Downloads"
Operating conditions
Ambient temperature [°C] -10...55
Storage temperature [°C] -25...70
Protection IP 65; IP 67
Max. immunity to extraneous light [klx] 10
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 3 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 3 V
EN 55011 Class A
Vibration resistance
EN 60068-2-6 Fc (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
MTTF [years] 82
Mechanical data
Weight [g] 3.5
Housing rectangular
Dimensions [mm] 1113 x 30 x 28
Materials housing: aluminium; front pane: PC
Length L [mm] 1113
Displays / operating elements
Display
transmitter 2 LED
receiver 3 LED
Accessories
Items supplied
mounting bracket: 2
slot nuts: 2
Nuts
Remarks
Pack quantity 1 pcs.
Electrical connection - receiver
Connection Connector: 1 x M12; coding: A
Electrical connection - transmitter
Connection Connector: 1 x M12; coding: A