O1D108

O1DLF3KG/IO-LINK

Photoelectric distance sensor

O1D108

O1DLF3KG/IO-LINK

  • Reliable optical distance measurement with background suppression
  • Two switching outputs, one of them programmable as analogue output
  • Scalable measuring range and window function
  • Use in applications with background suppression
  • Excellent price/performance ratio
  • ce
  • ukca
  • iolink
  • cul
Product characteristics
Laser protection class 2
Housing rectangular
Application
Application [m] 0.2...100
Electrical data
Operating voltage [V] 18...30 DC; ("supply class 2" to cULus)
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (programmable)
Max. current load per output [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4...20; (IEC 61131-2)
Max. load [Ω] 250
Analogue voltage output [V] 0...10; (IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Max. light spot width [mm] 25
Max. light spot height [mm] 25
Light spot dimensions refer to 18 m
Background suppression [m] < 100
Measuring/setting range
Measuring range [m] 0.2...18; (white paper 200 x 200 mm 90% remission)
Sampling rate [Hz] 1...33
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 6
Supported DeviceIDs
Type of operation DeviceID
default 811
Operating conditions
Ambient temperature [°C] -10...60
Protection IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 2
Notes on laser protection
Caution: laser light
Power: <= 4,0 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class: 2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 106
Mechanical data
Weight [g] 305
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Materials housing: diecast zinc; front pane: glass; LED window: PC
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
operation LED, green
distance value, programming alphanumeric display, 4-digit
Accessories
Accessories (optional)
Protective cover, E21133
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Other data
Parameter Setting range Factory setting
Uni m, inch m
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 0.20...18.00 1.00
nSP1 0.20...18.00 0.80
FSP1 0.20...18.00 1.20
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 0.20...18.00 2.00
nSP2 0.20...18.00 1.80
FSP2 0.20...18.00 2.20
ASP 0...18.00 0
AEP 0...18.00 18.00
rATE [Hz] 1...15 15
dS1 0...0.1...5 0
dr1 0...0.1...5 0
dS2 0...0.1...5 0
dr2 0...0.1...5 0
dFo 0...0.1...5 0
dIS d1...3 ; rd1...3; OFF d3
repeatability/accuracy
repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
0.20...1.0 m ± 0.45 cm ± 0.6 cm ± 1.5 cm ± 1.6 cm
1.00...2.00 m ± 0.5 cm ± 0.8 cm ± 1.5 cm ± 1.8 cm
2.00...4.00 m ± 1.25 cm ± 1.9 cm ± 2.25 cm ± 3.0 cm
4.00...6.00 m ± 2.0 cm ± 3.0 cm ± 3.0 cm ± 4.0 cm
6.00...10.00 m ± 3.5 cm ± 5.0 cm ± 4.5 cm ± 6.0 cm
10.00...18.00 m ± 5.0 cm ± 6.0 cm
Sampling rate 15 Hz
Extraneous light on the object < 10 klx
The values apply at
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10
repeatability/accuracy
repeatability of the measured values accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
0.20...1.0 m ± 0.45 cm ± 0.6 cm ± 1.5 cm ± 1.6 cm
1.00...2.00 m ± 0.5 cm ± 0.8 cm ± 1.5 cm ± 1.8 cm
2.00...4.00 m ± 1.6 cm ± 1.9 cm ± 2.5 cm ± 3.0 cm
4.00...6.00 m ± 2.4 cm ± 3.3 cm ± 3.5 cm ± 4.5 cm
6.00...10.00 m ± 5.0 cm ± 6.5 cm
Sampling rate 15 Hz
Extraneous light on the object < 40 klx
The values apply at
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10
In case of higher extraneous light on the object (up to 40 klx) the following specifications apply:
white (90 % remission) grey (18 % remission) black (6 % remission)
Measuring range 0.2...10 m 0.2...6 m 0.2...4 m