1. Homepage
  2. Products
  3. Process sensors
  4. Temperature sensors
  5. Cabled RTD probes, Type TS
  6. TS325A

TS325A

Temperature cable sensor with process connection

TS-300KEKD06...../3M/3D/3G

{{'OPTIONAL_INFO' | productAvailability | error}}

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team

  • Precise temperature measurement in containers, tanks and pipes
  • For applications in hazardous areas
  • Easy process adaptation via clamp fitting or protective tube
  • High precision across the entire temperature measurement range
  • dnv_gl
  • ce
Comprehensive technical data in pdf format

Technische Details
Product characteristics
Measuring range
-20...80 °C -4...176 °F
Process connection Diameter Ø 5 mm
Application
System screened cable
Measuring element 1 x Pt 100; (to DIN EN 60751, class B; operating current max. 10 mA)
Media liquids and gases
Minimum installation depth [mm] 15
Electrical data
Insulation rating [V] 2500; (Insulation between sensor housing and internal)
Protection class III
Measuring/setting range
Measuring range
-20...80 °C -4...176 °F
Note on measuring range
Measuring range for non-ATEX applications: -20...180 °C / -4...356 °F
Accuracy / deviations
Accuracy [K] ± (0,30 K + 0,005 x |t|)
Reaction times
Dynamic response T05 / T09 [s] 4 / 10; (according to DIN EN 60751)
Operating conditions
Ambient temperature [°C] -20...80
Protection IP 67
Tests / approvals
ATEX marking II 3D Ex tc IIIC T100°C Dc X
II 3G Ex nA IIC T5 Gc X
MTTF [years] 19348
Mechanical data
Weight [g] 88.6
Dimensions [mm] Ø 5 / L = 40
Material stainless steel (1.4404 / 316L)
Materials (wetted parts) stainless steel (1.4404 / 316L)
Process connection Diameter Ø 5 mm
Probe diameter [mm] 5
Remarks
Remarks
The values for accuracy apply to flowing water.
Pack quantity 1 pcs.
Electrical connection
Connection Cable: 3 m, silicone, screened