Measuring range |
|
||
---|---|---|---|
Process connection | Diameter Ø 5 mm |
System | screened cable |
---|---|
Measuring element | 1 x Pt 100; (to DIN EN 60751, class B; operating current max. 10 mA) |
Media | liquids and gases |
Minimum installation depth [mm] | 15 |
Insulation rating [V] | 2500; (Insulation between sensor housing and internal) |
---|---|
Protection class | III |
Measuring range |
|
||
---|---|---|---|
Note on measuring range |
|
Accuracy [K] | ± (0,30 K + 0,005 x|t|) |
---|
Dynamic response T05 / T09 [s] | 4 / 10; (according to DIN EN 60751) |
---|
Ambient temperature [°C] | -20...80 |
---|---|
Protection | IP 67 |
ATEX marking | II 3D Ex tc IIIC T100°C Dc X |
---|---|
II 3G Ex nA IIC T5 Gc X | |
MTTF [years] | 19025.9 |
Weight [g] | 89 |
---|---|
Dimensions [mm] | Ø 5 / L = 40 |
Material | stainless steel (1.4404 / 316L) |
Materials (wetted parts) | stainless steel (1.4404 / 316L) |
Process connection | Diameter Ø 5 mm |
Probe diameter [mm] | 5 |
Remarks |
|
|
---|---|---|
Pack quantity | 1 pcs. |
Connection | Cable: 3 m, silicone, screened |
---|