Service Center 800-441-8246
  1. Products
  2. TAP961

Temperature transmitter

TAP961

TAP040KLES30-PRAVG/US/

Temperature transmitter

TAP961

TAP040KLES30-PRAVG/US/

Article no longer available - archive entry
  • ce
  • ehedg
  • cul
  • 3a
Product characteristics
Measuring range
-25...150 °C -13...302 °F
Process connection G 1 Aseptoflex Vario
Application
System gold-plated contacts
Measuring element 1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one of the two sensor elements fails))
Application Suitable for all standard CIP and SIP processes
Media liquids and gases
Pressure rating [bar] 50
Minimum installation depth [mm] 15
No dead space yes
Electrical data
Operating voltage [V] 9...32 DC; (to SELV/PELV)
Current consumption [mA] < 15.6; (max. fault current : 21,8)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 35
Integrated watchdog yes
Outputs
Overload protection yes
Measuring/setting range
Probe length L [mm] 40
Measuring range
-25...150 °C -13...302 °F
Drift warning
0.2...5 °C 0.4...9 °F
Drift alarm
0.2...5 °C 0.4...9 °F
In steps of
0.05 °C 0.1 °F
Accuracy / deviations
Drift monitoring [K] ± 0,2 (-10...100°C); ± 0,3 (-25...-10/100...150°C) *); (probe completely inserted into the measured medium up to the sealing chamfer)
Temperature coefficient [% of the span / 10 K] < ± 0,01; (In case of deviation from the reference condition 25 ± 5 °C)
Reaction times
Dynamic response T05 / T09 [s] 6 / 13
Max. measuring/display cycle [ms] 600
Software / programming
Parameter setting options parameter setting to PROFIBUS PA profile temperature transmitter, version 3.01; I&M-Parameter; drift and diagnostic function
Operating conditions
Ambient temperature [°C] -25...70
Note on ambient temperature
electronics: -25...70 °C
Process connection: -32...170 °C
Storage temperature [°C] -40...85
Protection IP 68; IP 69K
Tests / approvals
EMC
DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
DIN EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
Note on approval
Including free 5-point calibration certificate.
Mechanical data
Material stainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts) stainless steel (1.4404 / 316L)
Process connection G 1 Aseptoflex Vario
Surface characteristics Ra/Rz of the wetted parts Ra: < 0.6
Remarks
Remarks
n.c. = not used
cULus - Class 2 source required
9...24 V DC when used inside the hazardous area
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated