Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
Measuring range |
8...2648 scfh |
0.15...44.15 scfm |
1...327.4 ft/s |
|
Process connection |
threaded connection 1/2" NPT DN15 |
Application |
Application |
for industrial applications |
Media |
compressed air |
Medium temperature [°F] |
14...140 |
Min. bursting pressure [psi] |
928 |
Pressure rating [psi] |
232 |
Electrical data |
Operating voltage [V] |
18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 80 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
1 |
Inputs / outputs |
Total number of inputs and outputs |
2; (configurable) |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
Outputs |
Output signal |
switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
150; (per output) |
Number of analog outputs |
1 |
Analog current output [mA] |
4...20; (scalable) |
Max. load [Ω] |
500 |
Pulse output |
consumed quantity meter |
Short-circuit protection |
yes |
Type of short-circuit protection |
yes (non-latching) |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
8...2648 scfh |
0.15...44.15 scfm |
1...327.4 ft/s |
|
Display range |
0...3178 scfh |
0...52.95 scfm |
0...393 ft/s |
|
Resolution |
2 scfh |
0.05 scfm |
0.2 ft/s |
|
Set point SP |
23...2648 scfh |
0.38...44.13 scfm |
2.8...327.3 ft/s |
|
Reset point rP |
10...2635 scfh |
0.16...43.91 scfm |
1.2...325.7 ft/s |
|
Analog start point ASP |
0...2119 scfh |
0...35.31 scfm |
0...261.9 ft/s |
|
Analog end point AEP |
530...2649 scfh |
8.83...44.14 scfm |
65.5...327.4 ft/s |
|
Low flow cut-off LFC |
3...28 scfh |
0.05...0.47 scfm |
0.4...3.5 ft/s |
|
In steps of |
1 scfh |
0.01 scfm |
0.1 ft/s |
|
Pressure monitoring |
Measuring range [psi] |
-15...232 |
Display range [psi] |
-15...290 |
Resolution [psi] |
1 |
Set point SP [psi] |
-13...232 |
Reset point rP [psi] |
-15...231 |
Analog start point [psi] |
-15...186 |
Analog end point [psi] |
32...232 |
In steps of [psi] |
1 |
Volumetric flow quantity monitoring |
Measuring range |
0...100000000 m³ |
0...353146667.2 scf |
|
Display range |
0...100000000 m³ |
0...353146667.2 scf |
|
Set point SP |
0.001...10000000 m³ |
0.05...353146667.2 scf |
|
Pulse value |
0.001...10000000 m³ |
0.05...353146667.2 scf |
|
In steps of |
|
Pulse length [s] |
0.002...2 |
Temperature monitoring |
Measuring range |
|
Display range |
-24...74 °C |
-11.2...165.2 °F |
|
Resolution |
|
Set point SP |
-9.7...60 °C |
14.6...140 °F |
|
Reset point rP |
-10...59.7 °C |
14...139.4 °F |
|
Analog start point |
-10...46 °C |
14...114.8 °F |
|
Analog end point |
|
In steps of |
|
Accuracy / deviations |
Temperature coefficient [1/K] |
± 0,07 % MW |
Accuracy (in the measuring range) |
class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 73 °F |
Repeatability |
± (0,4 % MW + 0,1 % MEW) |
Pressure monitoring |
Repeatability [% of the final value] |
± 0,2 |
Characteristics deviation [% of the final value] |
< ± 0,5; (BFSL = Best Fit Straight Line) |
Greatest TEMPCO of the span [% MEW / 10 K] |
± 0,15 |
Greatest TEMPCO of the zero point [% MEW / 10 K] |
± 0,25 |
Temperature monitoring |
Accuracy [K] |
± 0,5; (medium flow in the limit area of the flow measurement range) |
Reaction times |
Response time [s] |
0.1; (dAP = 0) |
Damping for the switching output dAP [s] |
0...5 |
Pressure monitoring |
Response time [s] |
0.05 |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
T09 = 0,5 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) |
SIO mode |
yes |
Required master port class |
A |
Process data analogue |
8 |
Process data binary |
2 |
Min. process cycle time [ms] |
7.2 |
Supported DeviceIDs |
Type of operation |
DeviceID |
default |
867 |
|
Operating conditions |
Ambient temperature [°F] |
32...140 |
Storage temperature [°F] |
-4...185 |
Max. relative air humidity [%] |
90 |
Protection |
IP 65; IP 67 |
Tests / approvals |
EMC |
|
Vibration resistance |
DIN EN 68000-2-6 |
5 g (10...2000 Hz) |
|
MTTF [years] |
183 |
UL approval |
UL approval number |
I012 |
File number UL |
E174189 |
|
Pressure equipment directive |
sound engineering practice; can be used for stable gases fluid group 2 |
Mechanical data |
Weight [g] |
731 |
Material |
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM |
Materials (wetted parts) |
stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
Process connection |
threaded connection 1/2" NPT DN15 |
Displays / operating elements |
Display |
|
Colour display 1,44", 128 x 128 pixels |
|
2 x LED, yellow |
|
Remarks |
Remarks |
MW = Measured value |
MEW = Final value of the measuring range |
Measuring, display and setting ranges refer to standard volume flow according to DIN ISO 2533. |
For information about installation and operation please see the operating instructions. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12 |