Service Center 800-441-8246
  1. Products
  2. Sensors
  3. Vacuum sensors and pressure sensors
  4. Industrial pressure / vacuum sensors, digital display | Types PN and PE
  5. PN7697

Pressure sensor with display

PN7697

PN-001BREN14-QFRKG/US/ /V

Pressure sensor with display

PN7697

PN-001BREN14-QFRKG/US/ /V

  • Two switching outputs, one of them with IO-Link communication interface
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
  • Convenient operation via buttons or parameter setting via IO-Link
Learn more
  • ce
  • ukca
  • cul
  • iolink
  • crn
Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range
0...1 bar 0...1000 mbar 0...14.5 psi 0...29.5 inHg 0...100 kPa
Process connection threaded connection 1/4" NPT external thread
Application
System gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25...80
Min. bursting pressure
30000 mbar 450 psi 880 inHg 3000 kPa
Pressure rating
10000 mbar 145 psi 290 inHg 1000 kPa
Type of pressure relative pressure
MAWP (for applications according to CRN)
10 bar 10000 mbar 145 psi 290 inHg 1000 kPa
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC [Hz] < 170
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range
0...1 bar 0...1000 mbar 0...14.5 psi 0...29.5 inHg 0...100 kPa
Factory setting / CMPT = 2
Set point SP
10...1000 mbar 0.1...14.5 psi 0.2...29.5 inHg 1...100 kPa
Reset point rP
5...995 mbar 0.05...14.45 psi 0.1...29.4 inHg 0.5...99.5 kPa
Min. difference between SP and rP
5 mbar 0.1 psi 0.2 inHg 0.5 kPa
In steps of
5 mbar 0.05 psi 0.1 inHg 0.5 kPa
Status_B High Resolution / CMPT = 3
Set point SP
8...1000 mbar 0.12...14.5 psi 0.2...29.5 inHg 0.8...100 kPa
Reset point rP
3...995 mbar 0.05...14.43 psi 0.1...29.4 inHg 0.3...99.5 kPa
Min. difference between SP and rP
5 mbar 0.08 psi 0.2 inHg 0.5 kPa
In steps of
1 mbar 0.01 psi 0.1 inHg 0.1 kPa
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,5
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,25
Long-term stability [% of the span] < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (-0...80 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,2; (-0...80 °C)
Reaction times
Response time [ms] < 3
Delay time programmable dS, dr [s] 0...50
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port class A; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operation DeviceID
Default 405
Factory setting / CMPT = 2 456
Status_B High Resolution / CMPT = 3 635
Note
For further information please see the IODD PDF file at "Downloads"
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms] 2.3
IO-Link resolution pressure [mbar] 1
IO-Link resolution pressure [MPa] 0.001
IO-Link process data (cyclical)
Function bit length
pressure 14
binary switching information 2
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms] 3
IO-Link resolution pressure [mbar] 0.5
IO-Link resolution pressure [MPa] 0.0005
IO-Link process data (cyclical)
Function bit length
pressure 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 260
UL approval
UL approval number J001
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 243.5
Material stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (1.4404 / 316L); ceramics; FKM
Min. pressure cycles 100 million
Tightening torque [Nm] 2...3 turns after hand-fastening; recommended tightening torque; Depends on lubrication, seal and pressure rating
Process connection threaded connection 1/4" NPT external thread
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display
Display unit 4 x LED, green (mbar, psi, kPa, inHg)
Switching status 2 x LED, yellow
Measured values alphanumeric display, red/green 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated