Application |
Application |
output of 3D image data |
Electrical data |
Operating voltage [V] |
20.4...28.8 DC; (EN 61131-2) |
Current consumption [mA] |
< 2400; (peak current pulsed; typical value: 420; maximum value: 1600) |
Power consumption [W] |
10; (typical value) |
Protection class |
III |
Integrated lighting |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Inputs |
Trigger |
24 V PNP/NPN (IEC 61131-2 Typ 3) |
Outputs |
Total number of outputs |
2 |
Number of digital outputs |
2; (configurable) |
Output function |
24 V PNP/NPN; (EN 61131-2) |
Max. current load per output [mA] |
100 |
Short-circuit protection |
yes |
Type of short-circuit protection |
yes (non-latching) |
Overload protection |
yes |
Monitoring range |
Operating distance [mm] |
300...8000 |
Note on operating distance |
object size: 200 x 200 mm |
reflectivity: 18 % |
|
image resolution [pixels] |
352 x 264 |
Angle of aperture |
60 x 45; (nominal value without lens distortion correction) |
max. reading rate [Hz] |
25 |
Measuring/setting range |
Measuring range [m] |
< 30 |
Software / programming |
Parameter setting options |
via PC with ifm Vision Assistant or XML-RPC |
Interfaces |
Communication interface |
Ethernet |
Ethernet |
Number of Ethernet interfaces |
1 |
Transmission standard |
10Base-T; 100Base-TX |
Transmission rate |
10; 100 |
Protocol |
TCP/IP |
Factory settings |
IP address: 192.168.0.69 |
subnet mask: 255.255.255.0 |
gateway IP address: 192.168.0.201 |
|
Operating conditions |
Ambient temperature [°C] |
-10...50 |
Storage temperature [°C] |
-40...85 |
Protection |
IP 65; IP 67 |
Max. immunity to extraneous light [klx] |
8; (with reduced measuring accuracy and repeatability: < 100) |
Tests / approvals |
EMC |
DIN EN 61000-6-4 |
radiation of interference / industrial environments |
DIN EN 61000-6-2 |
noise immunity / industrial environments |
|
Shock resistance |
DIN EN 60068-2-27 |
50 g / (11 ms) not repetitive |
DIN EN 60068-2-27 |
40 g / (6 ms) repetitive |
|
Vibration resistance |
DIN EN 60068-2-6 |
2 g / (10...150 Hz) |
DIN EN 60068-2-64 |
2.3 g RMS / (10...500 Hz) |
|
Photobiological safety |
exempt group; (DIN EN 62471) |
Electrical safety |
DIN EN 61010-2-201 |
|
|
|
electrical supply only via PELV circuits |
|
|
|
|
MTTF [years] |
45.02 |
Mechanical data |
Weight [g] |
772.5 |
Dimensions [mm] |
72 x 65 x 82.6 |
Material |
housing: diecast aluminium; front lens: Gorilla Glass; Function display: PA |
Image sensor |
PMD 3D ToF-Chip |
Displays / operating elements |
Display |
Function |
2 LED, green Ethernet Power |
Switching status |
2 LED, yellow OUT 1 OUT 2 |
|
Accessories |
Accessories (supplied) |
USB memory stick with software and documentation |
Protective covers |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection - Process connection |
|
Connector: 1 x M12 |
Electrical connection - Ethernet |
|
Connector: 1 x M12 |
Other data |
Field of view size |
|
without lens distortion correction |
|
with lens distortion correction |
|
Measuring range / distance [m] |
Length [m] |
Width [m] |
Length [m] |
Width [m] |
0.50 |
0.40 |
0.56 |
0.37 |
0.50 |
1.00 |
0.80 |
1.13 |
0.75 |
1.00 |
2.00 |
1.60 |
2.26 |
1.50 |
2.00 |
3.00 |
2.40 |
3.39 |
2.25 |
3.00 |
4.00 |
3.20 |
4.52 |
3.00 |
4.00 |
5.00 |
4.00 |
5.65 |
3.75 |
5.00 |
|