1. Homepage
  2. Products
  3. Position sensors
  4. Laser sensors
  5. O1D laser distance sensors for industrial automation
  6. O1D300

O1D300

Optical level sensor

O1DLF3KG/IO-LINK

{{'OPTIONAL_INFO' | productAvailability | error}}

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team

  • Reliable optical level measurement with high ranges up to 9.8 m
  • Scalable measuring range and window function
  • Two switching outputs, one of them programmable as analog output
  • Wide range of components for quick mounting and precise fine adjustment
  • Excellent price/performance ratio
  • ce
  • eac
  • cul
  • iolink
Comprehensive technical data in pdf format

Technische Details
Product characteristics
Electrical design PNP
Output function normally open / closed; (programmable)
Communication interface IO-Link
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Electrical data
Operating voltage [V] 18...30 DC; (cULus - Class 2 source required)
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / closed; (programmable)
Max. current load per output [mA] 200
Number of analog outputs 1
Analog current output [mA] 4...20; (IEC 61131-2)
Max. load [Ω] 250
Analog voltage output [V] 0...10; (IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Monitoring range
Max. light spot width [mm] 15
Max. light spot height [mm] 15
Light spot dimensions refer to 10 m
Background suppression [m] 10...100
Measuring/setting range
Measuring range [m] 0.2...10; (white paper 200 x 200 mm 90 % remission)
Sampling rate [Hz] 1...33
Interfaces
Communication interface IO-Link
Transmission type COM2 (38.4 kBaud)
SDCI standard IEC 61131-9
IO-Link revision 1.1
IO-Link device ID 813 d / 00 03 2Dh
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port class A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 6
Operating conditions
Ambient temperature [°C] -10...60
Protection IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 2
Notes on laser protection
Caution: Laser light
Power: <= 4,0 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class: 2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 107
Mechanical data
Weight [g] 325.5
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Material housing: diecast zinc; front lens: glass; LED window: PC
Lens alignment Side sensing
Displays / operating elements
Display
Switching status 2 x LED, yellow
Power LED, green
Distance, programming alphanumeric display, 4-digit
Accessories
Accessories (optional)
Protective cover, E21133
Remarks
Remarks
cULus - Class 2 source required
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12
Other data
Parameter Setting range Factory setting
Uni cm, m, inch cm
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 [cm] 20.0...999.5 100.0
rP1 [cm] 20.0...999.5 80.0
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 [cm] 20.0...999.5 200.0
rP2 [cm] 20.0...999.5 180.0
ASP [cm] 20.0...999.5 0
AEP [cm] 20.0...999.5 979.5
dr1 [s] 0...0.1...5 0
dr2 [s] 0...0.1...5 0
FOU1 ON ; OFF OFF
FOU2 ON ; OFF OFF
dFO [s] 0...0.1...5 0
EMP [cm] 20.0...999.5 20.0
cMEd [cm] 20.0...999.5 -
dIS ON ; OFF ON
mEAn [s] OFF ; 1...60 OFF
rATE [Hz] 1...33 15
Repeatability / Accuracy
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0...100.0 cm ± 0.45 cm ± 0.6 cm ± 1.5 cm ± 1.6 cm
100.0...200.0 cm ± 0.5 cm ± 0.8 cm ± 1.5 cm ± 1.8 cm
200.0...400.0 cm ± 1.6 cm ± 1.9 cm ± 2.5 cm ± 3.0 cm
400.0...600.0 cm ± 2.4 cm ± 3.3 cm ± 3.5 cm ± 4.5 cm
600.0...1000.0 cm ± 5.0 cm ± 6.5 cm
Sampling rate 15Hz
Extraneous light on the object < 40 klx
Repeatability / Accuracy
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0...200.0 cm ± 1.4 cm ± 1.4 cm ± 2.4 cm ± 2.4 cm
200.0...400.0 cm ± 2.5 cm ± 3.0 cm ± 3.5 cm ± 4.0 cm
400.0...600.0 cm ± 3.1 cm ± 4.5 cm ± 4.1 cm ± 5.5 cm
600.0...1000.0 cm ± 6.0 cm ± 7.0 cm
Sampling rate 15Hz
Extraneous light on the object 40...100 klx
Repeatability / Accuracy
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0...100.0 cm ± 0.4 cm ± 0.45 cm ± 1.4 cm ± 1.5 cm
100.0...200.0 cm ± 0.45 cm ± 0.6 cm ± 1.5 cm ± 1.6 cm
200.0...400.0 cm ± 1.35 cm ± 1.4 cm ± 2.3 cm ± 2.4 cm
400.0...600.0 cm ± 1.9 cm ± 2.1 cm ± 2.9 cm ± 3.1 cm
600.0...1000.0 cm ± 3.7 cm ± 4.7 cm
Sampling rate 1 Hz
Extraneous light on the object < 40 klx
Repeatability / Accuracy
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
20.0...200.0 cm ± 1.0 cm ± 1.0 cm ± 2.0 cm ± 2.0 cm
200.0...400.0 cm ± 1.8 cm ± 1.9 cm ± 2.8 cm ± 2.9 cm
400.0...600.0 cm ± 2.3 cm ± 2.7 cm ± 3.3 cm ± 3.7 cm
600.0...1000.0 cm ± 3.8 cm ± 4.8 cm
Sampling rate 1 Hz
Extraneous light on the object 40...100 klx
Range on black object (6 % remission) <= 400.0 cm
The values apply at
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — O1D300-05 — 22.03.2012 —