  • Reliable optical object detection with long ranges up to 10 m
  • Precise background suppression
  • Use in applications with background suppression
  • Excellent price/performance ratio
Learn more
  • ce
  • ukca
  • cul
  • iolink
Product characteristics
Laser protection class 2
Electrical data
Operating voltage [V] 10...30 DC
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1
Outputs
Total number of outputs 1
Electrical design PNP
Number of digital outputs 1
Output function normally open / closed; (programmable)
Max. current load per output [mA] 200
Type of short-circuit protection yes (non-latching)
Overload protection yes
Monitoring range
Max. light spot width [mm] 15
Max. light spot height [mm] 15
Light spot dimensions refer to 10 m
Background suppression [m] 10...100
Measuring/setting range
Measuring range [m] 0.2...10; (white paper 200 x 200 mm 90 % remission)
Sampling rate [Hz] 5
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 1
Min. process cycle time [ms] 6
Supported DeviceIDs
Type of operation DeviceID
default 807
Operating conditions
Ambient temperature [°C] -10...60
Protection IP 67
Tests / approvals
Laser protection class 2
Notes on laser protection
Caution: Laser light
Power: <= 4,0 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class: 2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 106
Mechanical data
Weight [g] 268.5
Dimensions [mm] 59 x 42 x 52
Material housing: diecast zinc; front lens: glass; LED window: PC
Displays / operating elements
Display
Switching status LED, yellow
Power LED, green
Distance, programming alphanumeric display, 4-digit
Accessories
Accessories (optional)
Protective cover, E21133
Remarks
Remarks
cULus - Class 2 source required
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Other data
Repeatability / Accuracy
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm ± 4.5 mm ± 6.0 mm ± 15.0 mm ± 16.0 mm
1000...2000 mm ± 5.0 mm ±8.0 mm ± 15.0 mm ± 18.0 mm
2000...4000 mm ± 16.0 mm ±19.0 mm ± 25.0 mm ± 30.0 mm
4000...6000 mm ± 24.0 mm ± 33.0 mm ± 35.0 mm ± 45.0 mm
6000...10000 mm ± 50.0 mm - ± 65.0 mm -
Extraneous light on the object < 40 klx
Repeatability / Accuracy
Repeatability of the measured values Accuracy
white (90 % remission) grey (18 % remission) white (90 % remission) grey (18 % remission)
200...2000 mm ± 14.0 mm ± 14.0 mm ± 24.0 mm ± 24.0 mm
2000...4000 mm ± 25.0 mm ± 30.0 mm ± 35.0 mm ± 40 mm
4000...6000 mm ± 31.0 mm ±45.0 mm ± 41.0 mm ± 55.0 mm
6000...10000 mm ± 60.0 mm - ± 70.0 mm -
Extraneous light on the object < 40...100 klx
Range on black object (6 % remission) <= 4000 klx
The values apply at
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10