Electrical design | NAMUR |
---|---|
Output function | normally closed |
Housing | Threaded type |
Dimensions [mm] | M10 x 1 / L = 33 |
Application | Ambient pressure max. 100 bar |
---|---|
Installation | installation on aluminium measuring wheel; (DN80) |
Pressure rating [bar] | 100 |
Connection at circuit amplifier | yes |
---|---|
Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
Nominal voltage DC [V] | 8.2; (1kΩ) |
Supply voltage DC [V] | 7.5...30 |
Current consumption [mA] | < 1; (disabled; conductive: > 2,1) |
Protection class | III |
Electrical design | NAMUR | |
---|---|---|
Output function | normally closed | |
Permanent current rating of switching output DC [mA] | 30 | |
Switching frequency DC [Hz] | 2000 | |
Notes on switching frequency [Hz] |
|
Hysteresis [% of Sr] | 1...15 |
---|
Ambient temperature [°C] | -20...60 |
---|---|
Protection | IP 67 |
EMC |
|
||
---|---|---|---|
Shock/vibration resistance | 30 g (11 ms) / 10-55 Hz (1 mm) |
Max. internal capacitance [nF] | 90 |
---|---|
Max. internal inductance [µH] | 100 |
Weight [g] | 24.8 |
---|---|
Housing | Threaded type |
Mounting | non-flush mountable |
Dimensions [mm] | M10 x 1 / L = 33 |
Thread designation | M10 x 1 |
Material | brass special coating; sensing face: LCP |
Pack quantity | 1 pcs. |
---|
Connection | Cable: 0.5 m; 2 x 0.14 mm², PVC |
---|