  • Five selectable positions of the sensing face
  • Long sensing range minimizes physical damage
  • Robust housing for use in harsh industrial environments
  • For use in materials handling
  • LED display for switching status and operation
  • ce
  • cul
Product characteristics
Electrical design PNP
Output function normally open
Sensing range [mm] 20
Housing rectangular
Dimensions [mm] 40 x 40 x 118
Application
System Magnetic-field immune
Magnetic-field immune yes
Electrical data
Operating voltage [V] 10...30 DC; (UL - Class 2 source required ; "supply limited voltage / current" acc. to UL)
Current consumption [mA] 20; (24 V)
Protection class II
Reverse polarity protection yes
Outputs
Electrical design PNP
Output function normally open
Max. voltage drop switching output DC [V] 3
Permanent current rating of switching output DC [mA] 200
Switching frequency DC [Hz] 5
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Monitoring range
Sensing range [mm] 20
Real sensing range Sr [mm] 20 ± 10 %
Operating distance [mm] 0...16.2
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminum: 0.3 / copper: 0.3
Hysteresis [% of Sr] 1...10
Switch-point drift [% of Sr] -10...10
Operating conditions
Ambient temperature [°C] -25...85
Note on ambient temperature
for UL application: ...70 °C
Max. height above sea level [m] 2000
Protection IP 68; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
EN 55011 class B
Vibration resistance
EN 60682-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance
EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistance
EN 60068-2-29 Eb 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature changes
EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
MTTF [years] 582.6
UL approval
Ta 0...70 °C
Enclosure type Type 1
voltage supply Class 2
File number UL E174191
Mechanical data
Weight [g] 253
Housing rectangular
Mounting flush mountable
Dimensions [mm] 40 x 40 x 118
Material PA 6.6; diecast zinc epoxy coated; sensing face: PA 6.6; LED window: PA; lower part: PA 6.6; screws: stainless steel
Displays / operating elements
Display
Switching status 1 x LED, yellow
Power 1 x LED, green
Remarks
Remarks
5 positions of the active zone possible
For use in NFPA 79 Applications only
Pack quantity 1 pcs.
Electrical connection - plug
Connection Connector: 1 x M12; coding: A