Service Center 800-441-8246
  1. Products
  2. CR3114

GPS/GSM modem with CAN interface

CR3114

R360/CANremote 3G/GPS

GPS/GSM modem with CAN interface

CR3114

R360/CANremote 3G/GPS

  • For the reliable wireless data exchange in mobile machines
  • Display and processing of position and route data
  • Data display and storage via internet portal
  • for the transfer of SMS messages and data packages
  • Connection to the machine control system via CAN interface
Article no longer available - archive entry
Alternative articles: CR3158 Product comparison: CR3114 / CR3158 When selecting an alternative article and accessories please note that technical data may differ!
  • ce
Application
Radio approval for USA; EU/RED
Note on radio approval
The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”.
Electrical data
Operating voltage [V] 6...32 DC
Current consumption [mA] < 600; (Ø 210 (24 V DC))
Interfaces
Number of CAN interfaces 1
Protocol CANopen
Mobilfunk
Transmission power [mW] 1928
Operating conditions
Ambient temperature [°C] -30...75
Storage temperature [°C] 15...25
Protection IP 65; (for unit with screwed-on connectors)
Tests / approvals
EMC
EN 61000-4-2 ESD 6 kV contact discharge / 8 kV air discharge
EN 61000-4-4 Burst 2 kV on supply lines / 1 kV on signal lines
EN 61000-4-5 Surge 0,5 kV on supply lines
EN 61000-4-6 HF conducted 10 V
EN 61000-4-3 HF radiated 10 V/m 80...1000 MHz / 3 V/m 1,4...2,7 GHz
ISO 10605: 2008 8/15 kV / 8 kV
ISO 11452-4 60 mA 20...80 MHz / 30 V/m 80...1000 MHz
ISO 7637-2 1, 2a, 2b, 3a, 3b, 4, 5
CISPR 16-2 class B
CISPR 25 radiated / met
Mechanical data
Weight [g] 754.5
Dimensions [mm] 120.5 x 126 x 42
Material aluminum powder-coated
Displays / operating elements
Display
status 4 x LED, red/green
Data memory
Real-time clock yes; with sleep and wakeup mode
Remarks
Remarks
Put the device into operation with connected antennas only.
Singapore Not approved for operation, for export only.
Pack quantity 1 pcs.
Electrical connection - antenna terminals
SMA socket Connector: 1 x SMA socket
Electrical connection - antenna terminals
FME connector Connector: 1 x FME connector
Electrical connection - plug
Connector: 1 x M12; coding: A