Service Center 800-441-8246
  1. Products
  2. Industrial communication
  3. AS-Interface I/O modules
  4. Field I/O with quick mounting technology
  5. AC5293

AS-Interface ClassicLine module with quick mounting technology

AC5293

ClassicLine 4DI-Y AUX 4DO-Y

AS-Interface ClassicLine module with quick mounting technology

AC5293

ClassicLine 4DI-Y AUX 4DO-Y

  • Easy toolless installation
  • Three selectable directions of the flat cable mounting
  • Clearly visible powerful LEDs for displaying operation, switching status and error
  • High protection rating for the requirements of harsh industrial environments
  • Robust M12 connectors for connecting sensors and actuators
  • ce
  • ukca
  • asib
  • cul
Application
Design Only for operation with AS-i masters with the profile M4
Application field installation
Electrical data
Operating voltage [V] 26.5...31.6 DC; (cULus - Class 2 source required)
Max. current consumption from AS-i [mA] 30
Max. current load total [A] 3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital inputs: 4; Number of digital outputs: 4
Inputs
Number of digital inputs 4
Input circuit of digital inputs PNP
Sensor supply of the inputs AUX
Voltage supply [V] 20...30; (via flat cable)
Max. total current rating of inputs [mA] 1000
Input current High [mA] 6...10
Input current low [mA] 0...2
Switching level high [V] > 11
Electrically separated yes
Digital inputs protected against short circuits yes
Outputs
Number of digital outputs 4
Circuit PNP
Voltage range DC [V] 20...30; (to PELV; via flat cable)
Max. current load per output [mA] 1000; (utilization category DC-13 (control of electromagnets): 20 W (IEC 60947-5-1))
Short-circuit proof yes
Electrically separated yes
Actuator supply outputs AUX
Operating conditions
Ambient temperature [°C] -25...70
Protection IP 67
Tests / approvals
EMC
EN 50295
IEC 61000-6-2
AS-i classification
AS-i version 3.0
AS-i addressing Addressing socket
Extended addressing mode yes
AS-i master profile M4
AS-i profile S-7.A.7
AS-i I/O configuration [hex] 7
AS-i ID code [hex] A.7
Data bits
Data bit D0 D1 D2 D3
Input 1 2 3 4
Socket I-1/2 I-1/2 I-2 I-3/4 I-3/4 I-4
Pin 4 2 4 4 2 4
Output 1 2 3 4
Socket O-1/2 O-1/2 O2 O-3/4 O-3/4 O-4
Pin 4 2 4 4 2 4
Mechanical data
Weight [g] 289
Type of mounting AS-i flat cable connection
Material PA; Piercing contacts: CuSn6 nickel-plated and tin-plated
Displays / operating elements
Display
Power LED, green Voltage AUX > 7 V
errors LED, red AUX 15 V ± 2 V
Function LED, yellow
Electrical connection
Module connection Flat cable
Accessories
Items supplied
lower part
Accessories (optional)
Protective cap: M12, E73004
Remarks
Pack quantity 1 pcs.
Electrical connection
quick mounting technology for AS-i flat cable: ; three selectable directions
Electrical connection - Inputs
Connection Connector: M12
Electrical connection - Outputs
Connection Connector: M12