Service Center 800-441-8246
  1. Products
  2. Industrial communication
  3. AS-Interface I/O modules
  4. All AS-interface I/O modules
  5. AC5228

AS-Interface Airbox with quick mounting technology

AC5228

AirBox 2x3/2 4DI-Y IP67

AS-Interface Airbox with quick mounting technology

AC5228

AirBox 2x3/2 4DI-Y IP67

  • For the decentralized triggering of cylinders and valve actuators
  • Combination of AS-i I/O module and solenoid valve
  • High energy efficiency due to decentralized application near the actuator
  • Reduced installation and wiring complexity
  • Easy toolless installation
  • ce
  • ukca
  • asib
  • cul
Application
Application field installation
Medium temperature [°C] -10...50
Electrical data
Operating voltage [V] 26.5...31.6 DC
Max. current consumption from AS-i [mA] 280
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital inputs: 4; Number of pneumatic outputs: 2
Inputs
Number of digital inputs 4
Input circuit of digital inputs PNP
Sensor supply of the inputs AS-i
Voltage supply [V] 20...30; (via flat cable)
Max. total current rating of inputs [mA] 200
Input current High [mA] 6...10
Input current low [mA] 0...2
Switching level high [V] > 11
Digital inputs protected against short circuits yes
Outputs
Number of pneumatic outputs 2
Actuator supply outputs AS-i
Operating conditions
Ambient temperature [°C] -10...55
Protection IP 65; IP 67
Tests / approvals
EMC
EN 50295
IEC 61000-6-2
MTTF [years] 287
AS-i classification
AS-i version 2.11; 3.0
AS-i addressing Addressing socket
Extended addressing mode yes
AS-i master profile M2; M3; M4
AS-i profile S-7.A.E
AS-i I/O configuration [hex] 7
AS-i ID code [hex] A.E
Data bits
Data bit D0 D1 D2 D3
Input 1 2 3 4
Socket I-1/2 I-1/2 I-2 I-3/4 I-3/4 I-4
Pin 4 2 4 4 2 4
pneumatic output 2 4 - -
Mechanical data
Weight [g] 378
Type of mounting quick mounting
Material PA; POM; Piercing contacts: CuSn6 nickel-plated and tin-plated
Pneumatic system 2 x 3/2-way slide valves (free from overlapping)
Operating pressure range [bar] 2...8
Operating pressure range [MPa] 0.2...0.8
Operating pressure range [psi] 29...116
Air flow at 6/5 bar [l/min] 500
Permissible compressed air non-lubricated compressed air class 6-3-1; lubricated compressed air class 6-3-4
Manual override pressing/releasing or pressing/turning/locking
Tube fittings 8 mm
Exhaust exhaust can be discharged through tube connection
Displays / operating elements
Display
Power LED, green
errors LED, red
Function LED, yellow
Electrical connection
Module connection Flat cable
Accessories
Items supplied
lower part
Accessories (optional)
Mounting plate:, E74999
Module lower part:, E75000
Protective cap: M12, E73004
sealing plug:, E75231
Silencer:, E75232
Push-in L-fitting:, E75228
Push-in T-fitting:, E75227
Remarks
Remarks
If not pneumatically operated, E75231 sealing plug must be inserted.
Avoid ingress of dirt and dust.
Do not connect any of the following points to an external potential:
L-, L+, I-1, I-2, I-3, I-4
The connections are electrically connected with the AS-i cable.
Please see the notes on compressed air and EMC/ESD under "Downloads"
Pack quantity 1 pcs.
Electrical connection
Connection quick mounting technology for AS-i flat cable: ; three selectable directions
Connection Connector: M12
Diagrams and graphs
Pneumatic symbol
2 x 3/2-way slide valves (free from overlapping)