Electrical data
Operating voltage [V] |
18...30 DC; (US) |
Current consumption [mA] |
50; (US) |
Protection class |
III |
Additional voltage supply [V] |
18...28 DC; (UA) |
Max. current consumption from additional supply [mA] |
3600; (UA) |
Inputs / outputs
Number of inputs and outputs |
Number of digital outputs: 12 |
Outputs
Number of digital outputs |
12; (6 x 2) |
Output function |
PNP |
Max. current load per output [mA] |
1800 |
Max. current load outputs total [A] |
3.6; (Max. current load per output side: 1800 mA) |
Electrically separated |
yes |
Interfaces
Communication interface |
IO-Link |
Supported DeviceIDs |
Type of operation |
DeviceID |
default |
893 |
|
IO-Link Device
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
SIO mode |
no |
Min. process cycle time [ms] |
5.6 |
Operating conditions
Ambient temperature [°C] |
-25...60 |
Storage temperature [°C] |
-25...70 |
Max. relative air humidity [%] |
90 |
Max. height above sea level [m] |
2000 |
Protection |
IP 65; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
Protection rating (NEMA 250) |
6P |
Pollution degree |
2 |
Chemical media |
ISO 16750-5 |
HLP, CC, DB, DC, DD, CA |
NEMA 250 5.13.1 |
AA |
|
Tests / approvals
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
|
DIN IEC 61131-9 |
|
|
Shock resistance |
|
Vibration resistance |
DIN EN 60068-2-64 |
|
DIN EN 60068-2-6 |
|
|
MTTF [years] |
63 |
Mechanical data
Weight [g] |
314 |
Dimensions [mm] |
26 x 59.3 x 152 |
Materials |
housing: PA grey; socket: stainless steel (316L/1.4404) |
Sealing material |
EPDM |
Displays / operating elements
Display |
operation |
LED, green |
errors |
LED, red |
function |
LED, yellow |
|
Electrical connection - IO-Link
X1 |
Connector: M12; coding: A |
Electrical connection - Outputs
X1.0...X1.5 |
Connector: M12; coding: A; Sealing: EPDM |
Electrical connection - power supply
X31 |
Connector: M12; coding: A |