1. Homepage
  2. Products
  3. Process sensors
  4. Pressure sensors
  5. Flush mountable for hydrostatic level measurement
  6. PI2692

Flush pressure sensor with display

PI-100-REA01-MFRKG/US/ /P

PI2692

Dear customer,
Unfortunately, this data sheet is not available in the requested language. If you have any further questions, you can contact us by e-mail.

Best regards
Your ifm team

  • Combined level measurement and point level detection with analogue / switching output
  • Resistant to high-pressure cleaning with aggressive cleaning agents
  • For use in high temperatures in process technology
  • Hygienic design for the requirements of the food and beverage industry
  • Flush mount installation in containers, tanks and pipes
  • ce
  • fda
  • ehedg
  • cul
  • 3a
Download
Technische Details
Application
Application hygienic systems
Installation freely rotatable housing 350°
Media viscous media and liquids with suspended particles; liquids and gases
Conditionally suitable for use in gases at pressures > 25 bar only on request
Medium temperature [°C] -25...125; (145 max. 1h)
Pressure rating
200 bar 2900 psi 20 MPa
Min. bursting pressure
650 bar 9425 psi 65 MPa
Type of pressure relative pressure
No dead space yes
Electrical data
Operating voltage [V] 18...32 DC
Current consumption [mA] < 50
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.5
Integrated watchdog yes
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; (configurable)
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 6
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible; (scalable 1:4)
Max. load [Ω] (Ub - 10 V) x 50
Analogue voltage output [V] 0...10, invertible; (scalable 1:4)
Min. load resistance [Ω] 2000
Electrical design PNP/NPN
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
-1...100 bar -15...1450 psi -0.1...10 MPa
Set point SP
-0.8...100 bar -13...1450 psi -0.08...10 MPa
Reset point rP
-1...99.8 bar -15...1448 psi > -0.1 MPa
Analogue start point
-1...75 bar -15...1088 psi -0.1...7.5 MPa
Analogue end point
24...100 bar 348...1450 psi 2.4...10 MPa
In steps of
0.1 bar 1 psi 0.01 MPa
Factory setting
SP1 = 25,0 bar rP1 = 23,0 bar
ASP = 0,0 bar AEP = 100,0 bar
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,5; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,5; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086)
Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span per 10 K] < ± 0,2; (0...70 °C)
Temperature coefficient span [% of the span per 10 K] < ± 0,2; (0...70 °C)
Response times
Response time [ms] < 100
Damping for the switching output dAP [s] 0.1...100
Damping for the analogue output dAA [s] 0.1...100
Step response time analogue output [ms] 25
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 67; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 0,5/1 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 20 g (10...2000 Hz)
MTTF [years] 163
Mechanical data
Weight [g] 451.8
Materials stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts) ceramics; PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Min. pressure cycles 100 million
Process connection threaded connection G 1 external thread sealing cone
Displays / operating elements
Display
Display unit 4 x LED, green
switching status LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit bar; psi; MPa; % of the span
Remarks
Remarks
The 3-A qualification is only valid if adapters with 3-A qualification are used for installation.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Kontakte: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI2692-00 — 21.11.2012