You probably do not come from: United Kingdom. If necessary, change to: United States
Service hotline 0208 213 2222
  1. Products
  2. Sensors
  3. Photoelectric sensors
  4. Distance sensors type O1D
  5. O1D106

Photoelectric distance sensor

O1D106

O1DLF3KG

Photoelectric distance sensor

O1D106

O1DLF3KG

  • Reliable optical distance measurement
  • Range up to 75 m for use on cranes
  • Two switching outputs, one of them programmable as analogue output
  • Excellent price/performance ratio
  • Wide range of components for quick mounting and precise fine adjustment
  • ce
  • ukca
  • cul
  • iolink
Product characteristics
Laser protection class 2
Housing rectangular
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (programmable)
Max. current load per output [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable IEC 61131-2)
Max. load [Ω] 250
Analogue voltage output [V] 0...10; (scalable IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Max. light spot width [mm] 150
Max. light spot height [mm] 150
Light spot dimensions refer to 75 m
Background suppression [m] 75...150
Measuring/setting range
Measuring range [m] 1...75; (Reflector E21159)
Sampling rate [Hz] 1...33
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 6
Supported DeviceIDs
Type of operation DeviceID
default 810
Operating conditions
Ambient temperature [°C] -10...60
Protection IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 2
Notes on laser protection
Caution: laser light
Power: <= 4,0 mW
Wave length: 650 nm
pulse: 1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class: 2
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 106
Mechanical data
Weight [g] 242.6
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Materials housing: diecast zinc; front pane: glass; LED window: PC
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
operation LED, green
distance value, programming alphanumeric display, 4-digit
Remarks
Remarks
operating voltage "supply class 2" according to cULus
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Other data
Parameter Setting range Factory setting
Uni m, feet m
OU1 Hno, Hnc, Fno, Fnc Hno
SP1 1.00...75.00 10.00
nSP1 1.00...75.00 8.00
FSP1 1.00...75.00 12.00
OU2 Hno, Hnc, Fno, Fnc, I, U I
SP2 1.00...75.00 20.00
nSP2 1.00...75.00 18.00
FSP2 1.00...75.00 22.00
ASP 0...75.00 0
AEP 0...75.00 75.00
rATE [Hz] 1...33 15
dS1 0...0.1...5 0
dr1 0...0.1...5 0
dS2 0...0.1...5 0
dr2 0...0.1...5 0
dFo 0...0.1...5 0.2
dIS d1...3; rd1...3; OFF d3
repeatability/accuracy
repeatability of the measured values accuracy
1...25 m ± 15 mm ± 35 mm
30 m ± 15 mm ± 35 mm
40 m ± 15 mm ± 35 mm
50 m ± 19 mm ± 39 mm
60 m ± 27 mm ± 47 mm
70 m ± 43 mm ± 63 mm
Sampling rate
Reflector 33 Hz
repeatability/accuracy
repeatability of the measured values accuracy
1...75 m ± 15 mm ± 35 mm
Sampling rate
Reflector 1 Hz
The values apply at
Extraneous light on the object < 100 klx
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 10