Output function | normally open / normally closed; (selectable) |
---|---|
Sensing range [mm] | sensing range programmable |
Housing | threaded type |
Dimensions [mm] | M30 x 1.5 / L = 92 |
Installation | detection through non-metallic container walls |
---|---|
Media | dry bulk material; liquids |
Medium temperature [°C] | -25...110 |
Frequency AC [Hz] | 47...63 |
---|---|
Operating voltage [V] | 30...250 AC |
Protection class | II |
Output function | normally open / normally closed; (selectable) |
---|---|
Max. voltage drop switching output AC [V] | 10 |
Minimum load current [mA] | 5 |
Max. leakage current [mA] | 2.5 (250 V AC) / 1.7 (110 V AC) |
Permanent current rating of switching output AC [mA] | 200; (250 (...40 °C)) |
Short-time current rating of switching output [mA] | 1500; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] | 5 |
Sensing range [mm] | sensing range programmable |
---|---|
Sensing range adjustable | yes |
Ambient temperature [°C] | -25...80 |
---|---|
Protection | IP 67 |
EMC |
|
---|
Housing | threaded type |
---|---|
Mounting | non-flush mountable |
Dimensions [mm] | M30 x 1.5 / L = 92 |
Thread designation | M30 x 1.5 |
Materials | PBT; PP |
Display |
|
---|
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
---|
Items supplied |
|
---|
Remarks |
|
|
---|---|---|
Pack quantity | 1 pcs. |
Connection | Connector: 1 x 1/2"; coding: C |
---|