Electrical data |
Operating voltage [V] |
10...36 DC |
Protection class |
II |
Reverse polarity protection |
yes |
Outputs |
Electrical design |
PNP/NPN |
Output function |
normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V] |
4.6 |
Minimum load current [mA] |
4 |
Max. leakage current [mA] |
0.5 |
Permanent current rating of switching output DC [mA] |
100 |
Switching frequency DC [Hz] |
1200 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Detection zone |
Sensing range [mm] |
4 |
Real sensing range Sr [mm] |
4 ± 10 % |
Operating distance [mm] |
0...3.25 |
Accuracy / deviations |
Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr] |
1...15 |
Switch point drift [% of Sr] |
-10...10 |
Operating conditions |
Ambient temperature [°C] |
-25...80 |
Protection |
IP 65; IP 66; IP 67 |
Tests / approvals |
EMC |
EN 61000-4-2 ESD |
- kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
0,5 kV line to line, Ri: 2 Ohm |
EN 61000-4-6 HF conducted |
10 V |
EN 55011 emission |
class B |
|
MTTF [years] |
2252 |
Mechanical data |
Weight [g] |
99.3 |
Housing |
rectangular |
Mounting |
non-flush mountable |
Dimensions [mm] |
40 x 12 x 26 |
Materials |
PBT |
Displays / operating elements |
Display |
switching status |
1 x LED, yellow |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Cable: 2 m, PUR; 2 x 0.5 mm² |