You probably do not come from: Australia.  If necessary, change to: United States
  1. Homepage
  2. Products
  3. Condition monitoring systems
  4. Systems for vibration monitoring and diagnostics
  5. Diagnostic electronics
  6. VSE100

Diagnostic electronics for vibration sensors

VSE100

DIAGNOSTIC ELECTRONICS

Diagnostic electronics for vibration sensors

VSE100

DIAGNOSTIC ELECTRONICS

  • For the reliable vibration monitoring of machines and equipment
  • Condition-based maintenance thanks to monitoring of unbalance, rolling element bearing or gear state
  • Inputs for the simultaneous detection of up to four vibration sensors
  • Two switching outputs for pre-alarm and main alarm
  • Analogue inputs for monitoring further measurement variables
{{ifmVariantName}}



  • ce
  • eac
  • cul
Technical details
Product characteristics
Frequency range [Hz] 0...12000
Application
Design parameter setting via PC software VES004
Application counter function
Electrical data
Operating voltage tolerance [%] 20
Operating voltage [V] 24 DC; (when using the IEPE input: 24 V + 20%; IEPE = Integrated Electronics Piezo Electric)
Current consumption [mA] 200; (24 V)
Protection class III
Inputs / outputs
Total number of inputs and outputs 16; (configurable)
Number of inputs and outputs Number of analogue inputs: 2; Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Input circuit of digital inputs HTL
Number of analogue inputs 2
Resolution of analogue input 12
Dynamic input - sampling rate [kSamples] 100
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal
Electrical design PNP
Number of digital outputs 2; (configurable)
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 100
Number of analogue outputs 1; (configurable)
Analogue current output [mA] 0...22; (0...10 V)
Max. load [Ω] 500
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Frequency range [Hz] 0...12000
Interfaces
Communication interface Ethernet
Protocol TCP/IP
Operating conditions
Ambient temperature [°C] 0...70
Storage temperature [°C] 0...70
Protection IP 20
Tests / approvals
EMC
EN 61000-6-2
EN 61000-6-3
EN 50178
MTTF [years] 89
Mechanical data
Weight [g] 460.6
Housing plastic housing
Type of mounting rail; (TH35/EN60715)
Dimensions [mm] 114 x 50 x 105
Materials PA
Data memories
History memory yes
Data memory buffered yes
Data memory type ring memory; FIFO
Real-time clock yes;
Memory location internal
Memory interval min. 1 min
Memory size 881664 data records
Accessories
Accessories (optional)
cross-over Ethernet patch cable for the direct connection to the PC
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection COMBICON: ; Maximum cable length: 250 m
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — VSE100-06 — 24.07.2019 —

Application Package Assistant

for VSE devices

APA V2.02.00

  • Name
  • Size
  • SHA-256
  • Type
  • Description
  • Name Application Package Assistant for VSE devices
  • Size 48.5 MB
  • SHA-256
    Datei-Hash SHA-256

    238e3d553513aa5ead4d343d116344ebc5cb0a5c9c6f78d2502f771a8fedecf9

  • Type .zip
  • Description System requirements: Windows 7 SP1, Windows 8 and 8.1, Windows 10, Win Server 2008 R2 SP1, Win Server 2012 R2, Win Server 2016, minimum resolution 1024 x 768 Pixel, 256 MB RAM. It is not possible to use VES003 and the Application Package Assistant simultaneously with one device. Required firmware for VSE devices: 0.6.11 or higher

VES004 diagnostic software

Configuration and visualisation of data provided by the VSE diagnostic electronics and VNB devices for vibration monitoring

VES004 V2.22.00

  • Name
  • Size
  • SHA-256
  • Type
  • Description
  • Name VES004
  • Size 85.7 MB
  • SHA-256
    Datei-Hash SHA-256

    b49f9734919cde9f8f893387f9fe8beceb558a7ffe3af548a2580c723cbfb9c0

  • Type .zip
  • Description System requirements: Windows 7 SP1, Windows 8 and 8.1, Windows 10, Win Server 2008 R2 SP1, Win Server 2012, Win Server 2012 R2, Win Server 2016, Win Server 2019, minimum resolution 1024 x 768 Pixel, 2 GB RAM. It is not possible to use VES003 and VES004 simultaneously with one device. Required firmware for VSE devices: 0.6.11 or higher

VSE002/VSE100 software

Current VSE002/VSE100 firmware

Firmware V0.13.14

  • Name
  • Size
  • SHA-256
  • Type
  • Description
  • Name As from AM device status
  • Size 45.5 kB
  • SHA-256
    Datei-Hash SHA-256

    3223b7c5ea5ab7cf83fc5457ff08cc57108edb0c6f528e1b3fd31db30c162035

  • Type .zip
  • Description Current firmware V0.13.14 for Octavis diagnostic electronic VSExxx up to AM device status. Please use VES004 for the update.