Product characteristics
Number of inputs and outputs |
Number of Pt100 inputs: 4 |
Measuring range [°C] |
-200...850 |
Electrical data
Operating voltage [V] |
20...29 DC |
Current consumption [mA] |
< 110 |
Electrical separation |
no |
Inputs / outputs
Number of inputs and outputs |
Number of Pt100 inputs: 4 |
Inputs
Number of Pt100 inputs |
4 |
Sensor supply of the inputs |
from operating voltage |
Measuring/setting range
Measuring range [°C] |
-200...850 |
Note on measuring range |
Pt100: -60...250 °C |
Ni sensors |
|
Accuracy / deviations
Measuring error [% of the final value] |
< ± 1 |
Interfaces
PROFIBUS
Transmission rate |
9,6...12000 kBit/s |
Operating conditions
Ambient temperature [°C] |
0...55 |
Storage temperature [°C] |
-25...85 |
Protection |
IP 67 |
Tests / approvals
EMC |
|
Vibration resistance |
IEC 68 |
parts 2-6 / IEC 68, parts 2-27 |
|
Mechanical data
Weight [g] |
308 |
Materials |
housing: PA 6; potting compound: PU; contact pins: brass gold-plated |
Electrical connection - PROFIBUS
|
Connector: M12; coding: B |
Electrical connection - Process connection
Connection |
Connector: M12; coding: A |
Electrical connection - power supply