Application
Application | fool-proof E-STOP to EN ISO 13850 |
---|
Electrical data
Operating voltage [V] | 26.5...31.6 DC |
---|---|
Current consumption [mA] | < 50 |
Inputs
Input circuit of digital inputs | PNP |
---|---|
Sensor supply of the inputs | AS-i |
Power supply [V] | 20 |
Input current Low [mA] | < 4 |
Digital inputs protected against short circuits | yes |
Outputs
Electrical design | AS-i |
---|
Operating conditions
Ambient temperature [°C] | -25...60 |
---|---|
Protection | IP 67 |
Safety classification
Complies with the requirements |
|
||
---|---|---|---|
Mission time TM [h] | 87600 |
AS-i classification
AS-i version | 2.1 |
---|---|
Extended addressing mode | no |
AS-i master profile | M3; M4 |
AS-i profile | S-7.B.E |
AS-i I/O configuration [hex] | 7 |
AS-i ID code [hex] | B.E |
AS-i certificate | 74601 |
Mechanical data
Weight [g] | 343.5 |
---|---|
Dimensions [mm] | 105 x 72 x 93.5 |
Materials | PC-GF20 |
Electrical connection
Module connection | M12 |
---|
Remarks
Pack quantity | 1 pcs. |
---|
Electrical connection
quick mounting technology for AS-i flat cable, IP 67: | |
Connector: M12; coding: A |