Application
Application |
parameter setting and analysis of units |
Electrical data
Nominal voltage DC [V] |
5; (USB) |
Current consumption [mA] |
< 1100; (USB) |
Protection class |
III |
Sensor supply |
24 V DC |
Sensor supply - AUX
Current rating per port [A] |
0.65 |
Sensor supply - USB
Current rating per port [A] |
0.15 |
Inputs / outputs
Number of inputs and outputs |
Number of digital inputs: 2; Number of digital outputs: 2 |
Inputs
Number of digital inputs |
2; (IO-Link port Class A : 1 x 2) |
Switching level high [V] |
11...30 |
Switching level low [V] |
0...5 |
Short-circuit protection digital inputs |
yes |
Outputs
Number of digital outputs |
2; (IO-Link port Class A: 1 x 2) |
Max. current load per output [mA] |
150 |
Short-circuit proof |
yes |
Interfaces
Communication interface |
IO-Link; USB |
Number of USB interfaces |
1 |
IO-Link Master
Transmission type |
COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud) |
IO-Link revision |
1.1 |
Number of ports class A |
1 |
Operating conditions
Ambient temperature [°C] |
-25...50 |
Storage temperature [°C] |
-25...85 |
Max. relative air humidity [%] |
90 |
Protection |
IP 65; IP 67 |
Tests / approvals
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-4 |
|
|
Shock resistance |
|
Vibration resistance |
DIN EN 60068-2-64 |
|
DIN EN 60068-2-6 |
|
|
MTTF [years] |
290 |
Mechanical data
Weight [g] |
143.7 |
Materials |
housing: PA; socket: PA; lock nut: nickel-plated brass |
Sealing material |
FKM |
Displays / operating elements
Display |
PWR |
1 x LED, green/red power supply |
IO-Link |
1 x LED, green/red communication |
DI/DO |
1 x LED, orange digital input/output |
|
Accessories
Accessories (optional) |
Switched-mode power supply 24 V DC:, M12 A-coded, E80121 |
USB cable: 1 m, E12689 |
Connection cable: 1 m, M12 A-coded, EVC012 |
|
Electrical connection - AUX
|
Connector: M12; coding: A |
Electrical connection - IO-Link
|
Connector: M12; coding: A; Sealing: FKM |
Electrical connection - USB