You probably do not come from: Vietnam. If necessary, change to: United States
  1. Products
  2. Sensors
  3. Level sensors
  4. Modular transmitter concept
  5. LR9020

Continuous level sensor (guided wave radar)

LR9020

LR0000--BR34A1DKG/US

Continuous level sensor (guided wave radar)

LR9020

LR0000--BR34A1DKG/US

  • For the reliable level control in tanks and containers
  • Suitable for water, oils and coolants
  • Precise analogue output and user-friendly communication via IO-Link
  • Modular system consisting of evaluation unit and probe
  • Adaptation to different container heights through shortening of the probe
  • User-friendly communication and parameterisation via IO-Link
Please see the technical note under "Downloads" For high process temperatures: The temperature at the process connection is decisive. The actual medium temperature may be higher.

Configure your solution

  • ce
  • ukca
  • cul
  • iolink
  • crn
Product characteristics
Number of inputs and outputs Number of analogue outputs: 1
Probe length L [mm] 100...1600
Process connection threaded connection G 3/4 external thread
Application
Special feature Gold-plated contacts
Application for industrial applications
Media Liquids
Dielectric constant of the medium ≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation)
Recommended media water; hydrous media; oils; oil-based media
Cannot be used for See the operating instructions, chapter "Function and features".
Process temperature [°C] -25...80; (90 < 1 h ; see note under remarks)
Pressure rating [bar] 16
Vacuum resistance [mbar] -1000
MAWP (for applications according to CRN) [bar] 16
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 25
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Measuring principle guided wave radar
Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal analogue signal; IO-Link
Electrical design PNP
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible
Max. load [Ω] 500
Analogue voltage output [V] 0...10, invertible
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection thermal, pulsed
Overload protection yes
Measuring/setting range
Probe length L [mm] 100...1600
Active range A [mm] L-40; (when set to oil and oil based media: L-60)
Inactive range I1 / I2 [mm] 30 / 10; (when set to oil and oil based media: 30 / 30)
Sampling rate [Hz] 4
Accuracy / deviations
Repeatability [mm] ± 5
Measuring error [mm] ± 7
Offset error [mm] 5
Resolution [mm] 1
Zero signal (voltage) [V] 0
Zero signal (current) [mA] 4
Full signal (voltage) [V] 10
Full signal (current) [mA] 20
Temperature drift per 10 K ± 0.2 %
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles no profile
SIO mode no
Required master port type A
Process data analogue 1
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
default 578
Operating conditions
Ambient temperature [°C] -25...60
Storage temperature [°C] -40...85
Protection IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3 in a closed metal tank
DIN EN 61000-6-4 in plastic or open metal tanks
Shock resistance
DIN EN 60068-2-27 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
Vibration resistance
DIN EN 60068-2-6 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
MTTF [years] 239
UL approval
UL Approval no. H009
File number UL E174191
Mechanical data
Weight [g] 470.9
Materials stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI
Materials (wetted parts) stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre
Process connection threaded connection G 3/4 external thread
Remarks
Notes Please see the technical note under "Downloads"; For high process temperatures: The temperature at the process connection is decisive. The actual medium temperature may be higher.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
Diagrams and graphs
Measurement deviation D at the limits of the active rod range