You probably do not come from: Vietnam. If necessary, change to: United States
  1. Products
  2. Safety technology
  3. Fail-safe inductive sensors
  4. Fail-safe inductive sensors
  5. GG714S

Fail-safe inductive sensor

GG714S

GIGA4008-2PS/SIL2/V4A/US

Fail-safe inductive sensor

GG714S

GIGA4008-2PS/SIL2/V4A/US

  • For ensuring machine safety
  • Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
  • No special actuator for electronic fail-safe sensors required
  • Connection to safety PLC, safe AS-i modules or safe evaluation units
  • ce
  • ukca
  • tuevnord
Product characteristics
Electrical design PNP
Output function 2 x OSSD (A1 and A2)
Enable zone [mm] 0...6.5
Housing threaded type
Dimensions [mm] M18 x 1 / L = 71.5
Application
Special feature Gold-plated contacts
Type of operation continuous operation (maintenance-free)
Safety-related function safe state when undamped
Application industrial application
Electrical data
Operating voltage [V] 19.2...30 DC
Rated insulation voltage [V] 30
Current consumption [mA] < 30
Protection class III
Reverse polarity protection yes
Max. power-on delay time [ms] 1000
Outputs
Electrical design PNP
Output function 2 x OSSD (A1 and A2)
Max. voltage drop switching output DC [V] 2.5; (30 mA)
Permanent current rating of switching output DC [mA] 100
Output data Interface type C class 1
Output voltage at 24 V compatible with EN 61131-2 inputs type 1, 2
Short-circuit protection yes
Overload protection no
Max. capacitive load CL_max [nF] 20
Detection zone
Enable zone [mm] 0...6.5
Safe switching-off distance s(ar) [mm] 11
Response times
Response time to safety request [ms] 1
Response time when approaching the enable zone [ms] 1
Risk time (response time for safety-related faults) [ms] 20
Operating conditions
Ambient temperature [°C] -40...70
Rate of temperature change [K/min] 0.5
Max. relative air humidity [%] briefly: 5...95 %; permanent: 5...70 %
Air pressure [kPa] 80...106
Max. height above sea level [m] 2000
Ionising radiation not permissible
Salt spray IEC 60068-2-52
Protection IP 65; IP 67; IP 69K; (with ifm socket duly screwed on)
UV radiation DIN ISO 4892-1, DIN ISO 4892-2
Chemical media
test according to ISO 16750-5
The following media were tested for 22 hours at 75 °C Liebherr Hydraulik 37
Liebherr Hydraulik Gear ATF
Liebherr Hydraulik Plus Arctic
diesel
biodiesel
brake fluid
urea
The following media were tested for 22 hours at 25 °C battery acid
cold cleaner
ammonia-based cleaner
The following media were tested for 2 hours at 25 °C wheel rim cleaner
Tests / approvals
EMC
IEC 60947-5-2
IEC 60947-5-3
EN 60947-5-3
EN 61000-4-2 ESD 6 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 20 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
EN 61000-4-8 30 A/m
EN 55011 class B
Shock resistance
IEC 60947-5-2
Vibration resistance
IEC 60947-5-2
Safety classification
Complies with the requirements
ISO 13849-1: 2015 category 2, PL d
IEC 61508 SIL 2
IEC 62061 SIL 2
Mission time TM [h] ≤ 87600
Mission time TM (additional indication)
10 years
PFH [1/h] 1,0E-07
Mechanical data
Weight [g] 130
Housing threaded type
Mounting non-flush mountable
Dimensions [mm] M18 x 1 / L = 71.5
Thread designation M18 x 1
Materials housing: stainless steel (1.4404 / 316L); sensing face: PBT; Protective cover: PPS GF40; LED window: PA; lock nuts: stainless steel (1.4404 / 316L)
Accessories
Items supplied
lock nuts: 2
Remarks
Remarks
Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.
(FE360 = ST37K) 24x24x1 mm
Pack quantity 1 pcs.
Electrical connection - plug
Connection Connector: 1 x M12; coding: A; Moulded body: PPS GF40; Contacts: gold-plated