- Products
- Industrial communication
- Fieldbus components
- IO-Link - Masters for field applications in factory automation
- AC6000
IO-Link master with AS-i interface
AC6000
IO-Link Master AS-i 4P IP67
IO-Link master with AS-i interface
AC6000
IO-Link Master AS-i 4P IP67
- For connection of up to four IO-Link devices
- Reliable transmission of machine data, process parameters and diagnostic data to the controller
- Simple replacement of units due to integrated parameter memory
- Robust housing for use in harsh industrial environments
{{ifmVariantName}}
Application | |||||||
---|---|---|---|---|---|---|---|
Application | field installation | ||||||
Daisy-chain function | voltage supply; fieldbus interface | ||||||
Electrical data | |||||||
Operating voltage [V] | 18...31.6 DC; (AS-i) | ||||||
Current consumption [mA] | 300...1500; (AUX) | ||||||
Max. current consumption from AS-i [mA] | 100 | ||||||
Protection class | III | ||||||
Max. current load total [A] | 1.1; (ports 1+2: 0,55 (AUX); ports 3+4: 0,55 (AUX)) | ||||||
Additional voltage supply [V] | 20...30 DC; (AUX) | ||||||
Inputs / outputs | |||||||
Total number of inputs and outputs | 8; (configurable) | ||||||
Number of inputs and outputs | Number of digital inputs: 8; Number of digital outputs: 4 | ||||||
Inputs | |||||||
Number of digital inputs | 8; (IO-Link Port Class A: 4 x 2) | ||||||
Sensor supply of the inputs | AUX | ||||||
Switching level high [V] | 11...30 | ||||||
Switching level low [V] | 0...5 | ||||||
Digital inputs protected against short circuits | yes | ||||||
Outputs | |||||||
Number of digital outputs | 4; (IO-Link Port Class A: 4 x 1) | ||||||
Max. current load per output [mA] | 300 | ||||||
Short-circuit proof | yes | ||||||
Actuator supply outputs | AUX | ||||||
Interfaces | |||||||
Communication interface | IO-Link; AS-i | ||||||
IO-Link Master | |||||||
Transmission type | COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud) | ||||||
IO-Link revision | 1.1 | ||||||
Number of ports class A | 4 | ||||||
Operating conditions | |||||||
Ambient temperature [°C] | -25...60 | ||||||
Storage temperature [°C] | -25...85 | ||||||
Max. relative air humidity [%] | 90 | ||||||
Protection | IP 65; IP 66; IP 67 | ||||||
Protection rating (NEMA 250) | 6P | ||||||
Degree of soiling | 2 | ||||||
Chemical media |
|
||||||
Tests / approvals | |||||||
EMC |
|
||||||
Shock resistance |
|
||||||
Vibration resistance |
|
||||||
MTTF [years] | 161 | ||||||
AS-i classification | |||||||
AS-i version | 2.11; 3.0 | ||||||
Extended addressing mode | no | ||||||
AS-i profile | S-7.4.E; (CTT1 input) | ||||||
Number of AS-i devices | 1...5 | ||||||
Further AS-i profiles |
|
||||||
Mechanical data | |||||||
Weight [g] | 247 | ||||||
Materials | housing: PA; socket: brass nickel-plated | ||||||
Electrical connection | |||||||
Module connection | M12 | ||||||
Remarks | |||||||
Remarks |
|
||||||
Pack quantity | 1 pcs. | ||||||
Electrical connection - Process connection | |||||||
IO-Link Port Class A X01...X04 | Connector: 4 x M12 | ||||||
Electrical connection - voltage supply IN | |||||||
X21 | Connector: 1 x M12 | ||||||
Electrical connection - voltage supply OUT | |||||||
X22 | Connector: 1 x M12 | ||||||