- Products
- TN2930
Product characteristics
Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 | ||
---|---|---|---|
Measuring range |
|
||
Process connection | threaded connection M18 x 1,5 Internal thread | ||
Installation length EL [mm] | 45 |
Application
System | gold-plated contacts |
---|---|
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class B) |
Application | detection of surface temperatures |
Media | liquids and gases |
Pressure rating [bar] | 30 |
Minimum installation depth [mm] | 15 |
Electrical data
Operating voltage [V] | 20...30 DC |
---|---|
Current consumption [mA] | < 66 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1.5 |
Integrated watchdog | yes |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
---|
Outputs
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analog signal; (configurable) |
Electrical design | PNP |
Number of digital outputs | 1 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20 |
Max. load [Ω] | 500 |
Analog voltage output [V] | 0...10 |
Min. load resistance [Ω] | 2000 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring/setting range
Probe length L [mm] | 45 | ||
---|---|---|---|
Measuring range |
|
||
Set point SP |
|
||
Reset point rP |
|
||
Analog start point |
|
||
Analog end point |
|
||
In steps of |
|
Resolution of switching output [K] | 0.5 |
---|---|
Resolution of analog output [K] | 0.125 |
Resolution of display [K] | 0.5 |
Accuracy / deviations
Switch point accuracy [K] | ± (Pt 1000 + 0,2 K) |
---|---|
Precision analog output [K] | ± (Pt 1000 + 0,2 K + 0,4%) |
Display accuracy [K] | ± (Pt 1000 + 0,2 K + ½ Digit) |
Temperature drift per 10 K [K] | 0.1 |
Reaction times
Dynamic response T05 / T09 [s] | 1 / 3; (according to DIN EN 60751) |
---|---|
Max. measuring/display cycle [ms] | 200 |
Software / programming
Adjustment of the switch point | Programming button |
---|---|
Parameter setting options | hysteresis / window; normally open / closed; min/max memory reset; Display unit; zero-point calibration; analog output selectable and scalable |
Operating conditions
Ambient temperature [°C] | -25...70 |
---|---|
Storage temperature [°C] | -40...100 |
Protection | IP 67 |
Tests / approvals
EMC |
|
||||||||
---|---|---|---|---|---|---|---|---|---|
Shock resistance |
|
||||||||
Vibration resistance |
|
Mechanical data
Housing | tubular |
---|---|
Dimensions [mm] | Ø 34 / L = 128.5 |
Material | stainless steel (1.4301 / 304); PBT; PC; EPDM/X; FKM |
Materials (wetted parts) | stainless steel (1.4404 / 316L) |
Process connection | threaded connection M18 x 1,5 Internal thread |
Probe diameter [mm] | 8.2 |
Installation length EL [mm] | 45 |
Displays / operating elements
Display |
|
---|
Remarks
Remarks |
|
|
---|---|---|
Pack quantity | 1 pcs. |
Electrical connection
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
---|