Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 | ||
---|---|---|---|
Measuring range |
|
||
Process connection | threaded connection G 2 DN50 flat seal |
System | gold-plated contacts | ||
---|---|---|---|
Application | Totalizer function; empty pipe detection; for industrial applications | ||
Installation | connection to pipe by means of an adapter | ||
Media | Conductive liquids; water; water-based media | ||
Note on media |
|
||
Medium temperature [°F] | 14...194 | ||
Pressure rating [bar] | 16 | ||
MAWP (for applications according to CRN) [bar] | 16 |
Operating voltage [V] | 18...32 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 150 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 5 |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|
Inputs | counter reset |
---|
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analog signal; pulse signal; frequency signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Analog voltage output [V] | 0...10; (scalable) |
Min. load resistance [Ω] | 2000 |
Pulse output | flow rate meter |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Frequency of the output [Hz] | 0.1...10000 |
Measuring range |
|
||
---|---|---|---|
Display range |
|
||
Resolution |
|
||
Set point SP |
|
||
Reset point rP |
|
||
Analog start point ASP |
|
||
Analog end point AEP |
|
||
Low flow cut-off LFC |
|
||
In steps of |
|
||
Measuring dynamics | 1:60 |
Pulse value | 0.02...80 E06 gal |
---|---|
In steps of | 0.02 gal |
Pulse length [s] | 0,016...2 |
Measuring range [°F] | -4...176 |
---|---|
Display range [°F] | -40...212 |
Resolution [°F] | 0.5 |
Set point SP [°F] | -2...176 |
Reset point rP [°F] | -3...175 |
Analog start point [°F] | -4...140 |
Analog end point [°F] | 32...176 |
In steps of [°F] | 0.5 |
Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
---|---|
Repeatability | ± 0,2% MEW |
Temperature drift | ± 0,0185 °F / K |
---|---|
Accuracy [K] | ± 1 (77 °F; Q > 4 gpm) |
Response time [s] | 0.35; (dAP = 0) |
---|---|
Delay time programmable dS, dr [s] | 0...50 |
Damping process value dAP [s] | 0...5 |
Dynamic response T05 / T09 [s] | T09 = 3 (Q > 4 gpm) |
---|
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/frequency/pulse output; Start-up delay; display can be deactivated; Display unit; empty pipe detection |
---|
Communication interface | IO-Link | ||||
---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 CDV | ||||
Profiles | Smart Sensor: Process Data Variable; Device Identification | ||||
SIO mode | yes | ||||
Required master port class | A | ||||
Process data analog | 3 | ||||
Process data binary | 2 | ||||
Min. process cycle time [ms] | 5 | ||||
Supported DeviceIDs |
|
Ambient temperature [°F] | 14...140 |
---|---|
Storage temperature [°F] | -13...176 |
Protection | IP 65; IP 67 |
EMC |
|
||||
---|---|---|---|---|---|
Shock resistance |
|
||||
Vibration resistance |
|
||||
MTTF [years] | 85 | ||||
UL approval |
|
||||
Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g] | 26 |
---|---|
Material | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U |
Materials (wetted parts) | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM |
Process connection | threaded connection G 2 DN50 flat seal |
Display |
|
---|
Items supplied |
|
---|
Remarks |
|
||
---|---|---|---|
Pack quantity | 1 pcs. |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
---|
Pressure loss
|
|
---|