Service Center 800-441-8246
  1. Products
  2. Sensors
  3. Flow sensors / flow meters
  4. SB mechatronic flowmeters for water and oil based media
  5. SBG232

Flow meter with fast response and display

SBG232

SBG12IF0FRKG

Flow meter with fast response and display

SBG232

SBG12IF0FRKG

  • Precise detection of flow and medium temperature
  • Suitable for water, coolants, oil and glycol solutions thanks to integrated measurement graphs
  • Very fast (~10 ms) response time
  • With switching output, analog output and frequency output
  • Clearly visible LED display with red/green color change
  • Convenient operation via buttons or parameter setting via IO-Link
Learn more
Please note the changed housing design!
  • ce
  • cul
  • iolink
  • crn
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
0.3...15 l/min 0.018...0.9 m³/h
Process connection threaded connection G 1/2
Application
System gold-plated contacts
Application for industrial applications
Media Liquids; water; glycol solutions; Coolants
Note on media
oil 1 with viscosity: 10 mm²/s (40 °C)
oil 2 with viscosity: 46 mm²/s (40 °C)
Medium temperature [°C] -10...100
Min. bursting pressure [bar] 160
Pressure rating [bar] 40
Pressure rating [MPa] 4
MAWP (for applications according to CRN) [bar] 40
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; frequency signal; IO-Link; (configurable)
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 150; (per output 2 x 200 (...60 °C); 2 x 250 (...40 °C))
Switching cycles (mechanical) 10 million
Number of analog outputs 1
Analog current output [mA] 4...20
Max. load [Ω] 500
Short-circuit protection yes
Overload protection yes
Frequency of the output [Hz] 0...10000
Measuring/setting range
Measuring range
0.3...15 l/min 0.018...0.9 m³/h
Display range
0...18 l/min 0...1.08 m³/h
Resolution
0.05 l/min 0.005 m³/h
Set point SP
0.1...15 l/min 0.005...0.9 m³/h
Reset point rP
0...14.9 l/min 0...0.895 m³/h
Frequency end point, FEP
1...15 l/min 0.06...0.9 m³/h
In steps of
0.05 l/min 0.005 m³/h
Frequency at the end point FRP [Hz] 10...10000
Measuring dynamics 1:50
Temperature monitoring
Measuring range [°C] -10...100
Display range [°C] -32...122
Resolution [°C] 1
Set point SP [°C] -9...100
Reset point rP [°C] -10...99
In steps of [°C] 1
Frequency start point, FSP [°C] -10...78
Frequency end point, FEP [°C] 12...100
Frequency at the end point FRP [Hz] 10...10000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) ± (4 % MW + 1 % MEW); (Q > 0,3 l/min; medium and operating temperature: +22 °C ± 4K)
Repeatability ± 1 % MEW
Temperature monitoring
Temperature drift 0,029 °C / K
Accuracy [K] 3 K (25°C; Q > 1 l/min)
Reaction times
Flow monitoring
Response time [s] 0.01
Damping process value dAP [s] 0...5
Damping for the analog output dAA [s] 0...5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 120 (Q > 1 l/min)
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; damping for the switching output / analog output; display can be rotated and switched off; standard unit of measurement; process value color
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time [ms] 5
Supported DeviceIDs
Type of operation DeviceID
default 560
Operating conditions
Ambient temperature [°C] 0...60
Note on ambient temperature
medium temperature < 80 °C
medium temperature < 100 °C: 0...40 °C
Storage temperature [°C] -15...80
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 5 g (10...2000 Hz)
MTTF [years] 145
UL approval
UL approval number I005
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 750
Material stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Process connection threaded connection G 1/2
Displays / operating elements
Display
Display unit 3 x LED, green
Switching status 2 x LED, yellow
Measured values alphanumeric display, red/green 4-digit
Programming alphanumeric display, 4-digit
Remarks
Remarks
Use of 200 micron filtration is recommended.
All data refer to water (20 °C).
MW = Measured value
MEW = Final value of the measuring range
Notes Please note the changed housing design!
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
Diagrams and graphs
Pressure loss
dP Pressure loss
Q volumetric flow quantity