Service Center 800-441-8246
  1. Products
  2. Sensors
  3. Radar sensors
  4. Radar range sensors
  5. R2D200

radar range sensor

R2D200

R2DBAF6KG/US/IO-Link

radar range sensor

R2D200

R2DBAF6KG/US/IO-Link

  • Long ranges and a wide temperature range
  • Reliable measurements even in precipitation, fog, dust and dirt
  • Simultaneous detection of distance and speed
  • Operating modes can be set in accordance with the specific application
  • Intuitive set-up and visualization of the measured data using the ifm Vision Assistant software
  • ce
  • fcc
  • iolink
  • cruus
Product characteristics
Communication interface IO-Link
Housing rectangular
Dimensions [mm] 80 x 80 x 45
Digital
Electrical design PNP/NPN; (configurable)
Output function normally open / closed; (configurable)
Application
Radio approval for EU/RED; United Kingdom; USA; Canada
Note on radio approval
The list of countries applying the European Radio Equipment Directive 2014/53/EU (RED) can be found under “Downloads”.
Electrical data
Operating voltage [V] 10...30 DC; (to SELV/PELV ; energy-limited circuits according to IEC/UL 61010-1 3rd ed. cl. 9.4)
Current consumption [mA] < 300; (mean value: 150 mA)
Power consumption [W] 21; (maximum)
Protection class III
Reverse polarity protection yes
Max. power-on delay time [ms] 1000
Operating frequency [GHz]
77...81
Maximum radiated average spectral density EIRP [dBm/MHz]
-9
Radiated peak power EIRP [dBm]
27
Inputs / outputs
Total number of inputs and outputs 3
Inputs
Inputs
IN1 activation/deactivation of the radar
Outputs
Total number of outputs 2
Output signal
OUT1 switching signal; IO-Link
OUT2 switching signal; analog signal
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Analog
Analog current output [mA] 4...20, invertible; (scalable)
Max. load [Ω] 500; (< 250 Ω: Ub 16...30 V DC; 250...500 Ω: Ub 18...30 V DC)
Analog voltage output [V] 0...10, invertible; (scalable)
Min. load [Ω] 2000
Digital
Electrical design PNP/NPN; (configurable)
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 200
Monitoring range
Range [m] 0.1...50; (based on E23014)
Angle of aperture cylindrical [°]
Horizontal 140
vertical 30
Measuring/setting range
Measuring range [m] 0.1...50; (see diagram:)
Sampling rate [Hz] 20
Accuracy / deviations
Hysteresis [mm] 5; (configurable)
Temperature coefficient analog output [% of the span / 10 K] ± 0,1
Repeatability analog output [% of the span]
< 0,1
Linearity error of analog output [% of the span]
± 0,15
Precision analog output [% of the span]
± 0,2 (in addition to the accuracy specifications in the further data section)
Software / programming
Parameter setting options only via IO-Link
Interfaces
Communication interface IO-Link
Transmission type COM3 (230,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Function class Description
0x0030 BLOB transfer
0x4000 Identification and Diagnosis
0x8101 Locator
0x8102 ProductURI
SIO mode yes
Required master port class A
Min. process cycle time [ms] 3.2
IO-Link process data (cyclical)
Function bit length
Distance 32
speed 32
Power 8
RCS 8
sensor inclination 1
device status 4
binary switching information 4
IO-Link functions (acyclical) application specific tag; operating hours counter; number of trigger events; internal temperature; ROI setting; Schaltverzögerungen; Sender abschaltbar
Supported DeviceIDs
Type of operation DeviceID
default 1519
Note
For further information please see the IODD PDF file at "Downloads"
Operating conditions
Ambient temperature [°C] -40...80
Note on ambient temperature
without using the analog output: -40...85 °C
Storage temperature [°C] -40...85
Protection IP 65; IP 66; IP 67; IP 69K; (with mounted connectors or protective caps)
Tests / approvals
EMC
DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD
DIN EN 61000-4-3 HF radiated 10 V/m
DIN EN 61000-4-4 Burst 2 kV
DIN EN 61000-4-6 HF conducted 10 V
DIN EN 61000-6-2 noise immunity / industrial environments
EN 55032 emission class A
Impact resistance
IEC 62262 IK06 (1J)
Vibration resistance
DIN EN 60068-2-6 Fc 10 g 10 frequency cycles, 1 octave/minute, in 3 axes
Shock resistance
DIN EN 60068-2-27 Ea 50 g 11 ms half-sine; 10 shocks each in every direction along the 3 coordinate axes
Continuous shock resistance
DIN EN 60068-2-29 Eb 40 g 6 ms half-sine; 4,000 shocks each in every direction along the 3 coordinate axes
Fast temperature changes
DIN EN 60068-2-14 Na TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 30 s; 300 cycles
Salt spray test
DIN EN 60068-2-11 Ka 8 test cycles
Electrical safety
DIN EN 61010-2-201 electric shock / electrical supply only via SELV/PELV circuits
MTTF [years] 53
UL approval
Ta -40...65 °C
File number UL E205959
Mechanical data
Weight [g] 397.2
Housing rectangular
Mounting flush mountable
Dimensions [mm] 80 x 80 x 45
Material housing: PA; radome: PEI; sealing: HNBR
Displays / operating elements
Display
Switching status 2x LED, yellow
Power 1x LED, green
errors 1x LED, red
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Diagrams and graphs
Monitoring range
1: azimuth
2: elevation
conditions
Reflector: 4.3“ Trihedral Corner Reflector (SAJ043-S1)
RCS: 10 dBm²
Distance: 5 m
operating frequency: 79 GHz
Other data
Operating mode standard Long range, high velocity
max. distance 0.1...20 m 0.25...35 m
distance resolution 100 mm 350 mm
horizontal angular resolution (azimuth ) 10 ° 10 °
distance accuracy ± 5 mm ± 15 mm
max. velocity ± 6 m/s ± 15 m/s
velocity resolution ± 0.20 m/s ± 0.38 m/s
speed accuracy ± 0.01 m/s ± 0.04 m/s
Switching frequency 20 Hz 20 Hz
Distance based on E23013
Resolution for the detection of two objects of the same size
Accuracy for a strong, point-shaped target