Service Center 800-441-8246
  1. Products
  2. PY9000

Pressure sensor with display

PY9000

PY-600-SE MFRKG/US/ /V

Pressure sensor with display

PY9000

PY-600-SE MFRKG/US/ /V

  • Suited for use in homogenizer processes
  • Intuitive, user-friendly handling
  • Analog output and switching output for alarm function
  • Integrated, clearly readable display
  • With long-term stability thanks to high overload protection
Article to be discontinued
Discontinuation date: 03/31/2024
Alternative articles: PY9060 Product comparison: PY9000 / PY9060 When selecting an alternative article and accessories please note that technical data may differ!
  • ce
  • fda
  • ukca
  • ec19352004
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range [bar] 0...600
Process connection homogenizer connection
Application
System gold-plated contacts
Application flush mountable for the food and beverage industry
Media liquids and gases
Conditionally suitable for For gaseous media the application is limited to max. 25 bar.
Medium temperature [°C] -25...100; (145 max 1h)
Min. bursting pressure [bar] 1200
Pressure rating [bar] 800
Type of pressure relative pressure
Electrical data
Operating voltage [V] 20...30 DC
Current consumption [mA] < 65
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] < 170
Number of analog outputs 1
Analog current output [mA] 4...20; (scalable 1:4)
Max. load [Ω] (Ub - 10 V) / 20 mA
Analog voltage output [V] 0...10; (scalable 1:4)
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range [bar] 0...600
Set point SP [bar] 6...600
Reset point rP [bar] 3...597
Analog start point [bar] 0...240
Analog end point [bar] 150...600
In steps of [bar] 3
Accuracy / deviations
Switch point accuracy [% of the span] < ± 1,0; (Turn down 1:1)
Repeatability [% of the span] < ± 0,25; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 1,0; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span] < ± 0,5; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 1,0; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,25; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (0...80 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,2; (0...80 °C)
Reaction times
Response time [ms] < 3
Damping process value dAP [s] 0...4
Damping for the analog output dAA in steps [s] 0 - 0; 1 - 0; 5 - 2
Max. response time analog output [ms] 3
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; Zero point; span
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 0,5/1 kV
EN 61000-4-6 HF conducted 10 V
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 145
Mechanical data
Weight [g] 384
Material stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PA; FKM; EPDM/X
Materials (wetted parts) stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); FKM
Min. pressure cycles 50 million
Process connection homogenizer connection
Displays / operating elements
Display
Display unit 3 x LED, green
Switching status 2 x LED, yellow
Function display alphanumeric display, 4-digit
Measured values alphanumeric display, 4-digit
Display unit bar; psi; MPa
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated