Laser protection class | 2 |
---|---|
Housing | rectangular |
Operating voltage [V] | 18...30 DC |
---|---|
Current consumption [mA] | < 150 |
Protection class | III |
Reverse polarity protection | yes |
Typ. lifetime [h] | 50000 |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|
Total number of outputs | 2 |
---|---|
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / closed; (programmable) |
Max. current load per output [mA] | 200 |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (IEC 61131-2) |
Max. load [Ω] | 250 |
Analog voltage output [V] | 0...10; (IEC 61131-2) |
Min. load resistance [Ω] | 5000 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Max. light spot width [mm] | 6 |
---|---|
Max. light spot height [mm] | 6 |
Light spot dimensions refer to | 3,5 m |
Background suppression [m] | 0...4 |
Measuring range [m] | 0.2...3.5; (black glossy surfaces) |
---|---|
Sampling rate [Hz] | 1...50; (preset: 5) |
Communication interface | IO-Link | ||||
---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 | ||||
Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis | ||||
SIO mode | yes | ||||
Required master port class | A | ||||
Process data analog | 2 | ||||
Process data binary | 3 | ||||
Min. process cycle time [ms] | 6 | ||||
Supported DeviceIDs |
|
Ambient temperature [°C] | -10...60 |
---|---|
Protection | IP 67 |
EMC |
|
||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Laser protection class | 2 | ||||||||||||||||||||
Notes on laser protection |
|
||||||||||||||||||||
MTTF [years] | 173 |
Weight [g] | 241.7 |
---|---|
Housing | rectangular |
Dimensions [mm] | 59 x 42 x 52 |
Material | housing: diecast zinc; front lens: glass; LED window: PC |
Lens alignment | Side sensing |
Display |
|
---|
Accessories (optional) |
|
---|
Remarks |
|
|
---|---|---|
Pack quantity | 1 pcs. |
Connection | Connector: 1 x M12; coding: A |
---|
Parameter | Setting range | Factory setting |
Uni | mm, m, inch | mm |
OU1 | Hno, Hnc, Fno, Fnc | Hno |
SP1 [mm] | 200...3500 | 1000 |
nSP1 [mm] | 200...3500 | 800 |
FSP1 [mm] | 200...3500 | 1200 |
OU2 | Hno, Hnc, Fno, Fnc, I, U | I |
SP2 [mm] | 200...3500 | 2000 |
nSP2 [mm] | 200...3500 | 1800 |
FSP2 [mm] | 200...3500 | 2200 |
ASP [mm] | 0...3500 | 0 |
AEP [mm] | 0...3500 | 3500 |
rATE [Hz] | 1...50 | 5 |
dS1 [s] | 0...0.1...5 | 0 |
dr1 [s] | 0...0.1...5 | 0 |
dS2 [s] | 0...0.1...5 | 0 |
dr2 [s] | 0...0.1...5 | 0 |
dFo [s] | 0...0.1...5 | 0 |
dIS | d1...3 ; rd1...3; OFF | d3 |
Repeatability of the measured values | Accuracy | |||
white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | |
200...1000 mm | ± 6.5 mm | ±7.5 mm | ± 32 mm | ± 40 mm |
1000...2000 mm | ± 8 mm | ±9.5 mm | ± 33 mm | ± 40 mm |
2000...3000 mm | ± 17 mm | ±19 mm | ± 42 mm | ± 50 mm |
3000...3500 mm | ± 23 mm | ±25 mm | ± 50 mm | ± 55 mm |
The values apply at | |
constant ambient conditions | 23 °C / 960 hPa |
minimum power-on time in minutes | 10 |