Service Center 800-441-8246
  1. Products
  2. Sensors
  3. Level sensors
  4. Residue suppression level switches for sanitary applications, Type LM
  5. LMT192

Level sensor for limit detection with overspill protection (German Federal Water Act)

LMT192

LMCCE-A12E-QPKG-2/US

Level sensor for limit detection with overspill protection (German Federal Water Act)

LMT192

LMCCE-A12E-QPKG-2/US

  • For the reliable level control in tanks and containers
  • Hygienic design for the requirements of the food and beverage industry
  • Use in liquid and viscous media and bulk materials
  • Differentiation of media by parameterization of the switching outputs
  • Reliable suppression of deposits or foam
  • User-friendly communication and parameterization via IO-Link
Learn more
  • ce
  • ukca
  • whg
  • cul
  • iolink
Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Factory setting water-based media
Process connection threaded connection G 1/2 sealing cone
Application
System gold-plated contacts
Media Liquids
Recommended media water; water-based media; oils; oil-based media
Cannot be used for See the operating instructions, chapter "Function and features".
Probe length [mm] 38
Tank pressure [bar] -1...40; (Applications according to the German Federal Water Act (WHG): -0,5...10 bar)
Oil
Medium temperature [°C] -25...100; (Applications according to the German Federal Water Act (WHG) 0...100 °C)
Medium temperature short time [°C] -25...150; (1 h; Applications according to the German Federal Water Act (WHG): 0...100 °C)
Water
Medium temperature [°C] -25...85; (Applications according to the German Federal Water Act (WHG): 0...85 °C)
Medium temperature short time [°C] -25...150; (1 h; Applications according to the German Federal Water Act (WHG): 0...100 °C)
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Measuring principle capacitive
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; IO-Link
Electrical design PNP
Number of digital outputs 2
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Factory setting water-based media
Reaction times
Response time [s] < 0.5
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port class A
Process data analog 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
default 449
Operating conditions
Ambient temperature [°C] -20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C] -40...85
Protection IP 68; IP 69K
Tests / approvals
Approval WHG; General building authority approval; overflow prevention
EMC
DIN EN 61000-6-2
DIN EN 61000-6-4 open tanks
DIN EN 61000-6-3 closed tanks
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 222.77
UL approval
UL approval number H001
Mechanical data
Weight [g] 249
Dimensions [mm] Ø 30 / L = 125
Material stainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts) PEEK; surface characteristics: Ra < 0,8 / Rz 4
Process connection threaded connection G 1/2 sealing cone
Displays / operating elements
Display
Switching status LED, yellow
operating status LED, green
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated