Product characteristics
Output function | normally open |
---|---|
Sensing range [mm] | 10 |
Dimensions [mm] | M30 x 1.5 / L = 81 |
Application
Application | simple evaluation of rotating and linear movement with regard to underspeed; blocking |
---|
Electrical data
Nominal voltage AC [V] | 20...250 |
---|---|
Nominal voltage DC [V] | 20...250 |
Reverse polarity protection | no |
Outputs
Total number of outputs | 1 |
---|---|
Output function | normally open |
Max. voltage drop switching output DC [V] | 6.5 |
Minimum load current [mA] | 6 |
Max. leakage current [mA] | 1.5 |
Permanent current rating of switching output AC [mA] | 250; (350 AC (...50 °C)) |
Permanent current rating of switching output DC [mA] | 100 |
Short-time current rating of switching output [mA] | 2200 |
Short-circuit proof | no |
Overload protection | no |
Monitoring range
Sensing range [mm] | 10 |
---|---|
Sensing range adjustable | no |
Measuring/setting range
Setting range [Imp/min] | 5...300 |
---|
Accuracy / deviations
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.3 |
---|---|
Hysteresis [% of Sr] | 10 |
Reaction times
Start-up delay [s] | 12 |
---|---|
Max. damping frequency [Imp/min] | 1500 |
Software / programming
Adjustment of the switch point | multiturn potentiometer |
---|
Operating conditions
Ambient temperature [°C] | -25...80 |
---|---|
Protection | IP 67 |
Mechanical data
Weight [g] | 255.8 |
---|---|
Mounting | flush mountable |
Dimensions [mm] | M30 x 1.5 / L = 81 |
Thread designation | M30 x 1.5 |
Material | brass special coating; PBT |
Tightening torque [Nm] | 50 |
Displays / operating elements
Display |
|
---|
Electrical connection
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
---|
Remarks
Remarks |
|
---|
Electrical connection
Connection | Cable: 2 m, PVC; 2 x 0.5 mm² |
---|