  • Easy toolless installation
  • Three selectable directions of the flat cable mounting
  • Clearly visible powerful LEDs for displaying operation, switching status and error
  • High protection rating for the requirements of harsh industrial environments
  • Robust M12 connectors for connecting sensors and actuators
  • ce
  • eac
  • asib
  • cul
Download
Technische Details
Electrical data
Operating voltage [V] 26.5...31.6 DC; (cULus - Class 2 source required)
Max. current consumption from AS-i [mA] 250
Max. current load total [A] 3
Additional voltage supply [V] 15...30 DC; (AUX)
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital inputs: 4; Number of digital outputs: 3
Inputs
Number of digital inputs 4
Input circuit of digital inputs PNP
Voltage supply [V] 18...30
Max. total current rating of inputs [mA] 200
Input current High [mA] 6...10
Input current low [mA] 0...2
Min. switching level high signal [V] 11
Digital inputs protected against short circuits yes
Sensor supply of the inputs AS-i
Outputs
Number of digital outputs 3
Circuit PNP
Voltage range DC 15...30; (to PELV)
Max. current load per output [mA] 1000; (utilization category DC-13 (control of electromagnets): 20 W (IEC 60947-5-1))
Short-circuit proof yes
Electrically separated yes
Operating conditions
Ambient temperature [°C] -25...70
Protection IP 67
Tests / approvals
EMC
EN 50295
IEC 61000-6-2
MTTF [years] 162
AS-i classification
AS-i version 2.11 + 3.0
AS-i addressing Addressing socket
Extended addressing mode possible yes
AS-i profile S-7.A.E
AS-i I/O configuration [hex] 7
AS-i ID code [hex] A.E
AS-i certificate pending yes
Data bits
Data bit D0 D1 D2 D3
Input 1 2 3 4
Socket I-1 I-2 I-3 I-4
Pin 4 4 4 4
Output 1 2 3 -
Socket O-1 O-2 O-3 -
Pin 4 4 4 -
Mechanical data
Weight [g] 309.5
Type of mounting AS-i flat cable connection
Material PA; Piercing contacts: CuSn6 nickel-plated and tin-plated
Displays / operating elements
Display
Power LED, green
errors LED, red
Function LED, yellow
Accessories
Accessories (supplied)
lower part
Accessories (optional)
Protective cap: M12, E73004
Remarks
Remarks
Inputs and outputs must be electrically isolated.
Pack quantity 1 pcs.
Electrical connection
quick mounting technology for AS-i flat cable: ; three selectable directions
Electrical connection - Outputs
Connector: M12
Electrical connection - Inputs
Connector: M12
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — AC5274-00 — 20.12.2010 —