{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — ZZ0057-01 — 11.08.2022","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[],"connectionDescriptionAttachable":"","connectionDescriptionCable":"","connectionDescriptionPlug":"Connector: 3 x M12; Contacts: gold-plated","connectionSubSectionList":[],"pinLayoutImage":"","pinLayoutImageDesc":"Connector: 3 x M12; Contacts: gold-plated","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"threaded connection M22 x 1,5 external thread","valueList":null}],"name":"Process connection for welding gun"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"threaded connection M22 x 1,5 external thread","valueList":null}],"name":"Process connection for water supply"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_stroemung-messbereich-lpmin-bereich","keyOrName":"at_stroemung-messbereich-lpmin-bereich","name":"Measuring range","tableValue":null,"type":"string","uom":"[l/min]","value":"0...50","valueList":null}],"name":"Flow monitoring"}],"sectionName":"Product characteristics"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_besondere-eigenschaft","keyOrName":"at_besondere-eigenschaft","name":"Special feature","tableValue":null,"type":"string","uom":"","value":"gold-plated contacts","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"Industrial applications; Cooling water control","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-montage","keyOrName":"at_einsatzbereich-montage","name":"Installation","tableValue":null,"type":"string","uom":"","value":"connection to pipe by means of an adapter; tube connection","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_messgroessen","keyOrName":"at_messgroessen","name":"Measuring parameters","tableValue":null,"type":"string","uom":"","value":"flow; temperature; pressure; totalizer","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_regelung","keyOrName":"at_regelung","name":"Control","tableValue":null,"type":"string","uom":"","value":"manual","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_medien-tag","keyOrName":"at_medien-tag","name":"Media","tableValue":null,"type":"string","uom":"","value":"water; glycol solutions","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mediumtemp-cel","keyOrName":"at_mediumtemp-cel","name":"Medium temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-10...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_druckfestigkeit-bar","keyOrName":"at_druckfestigkeit-bar","name":"Pressure rating","tableValue":null,"type":"decimal","uom":"[bar]","value":"10","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_komponenten","keyOrName":"at_komponenten","name":"Components","tableValue":[[["td","SU ultrasonic flowmeters for water and oil based media, SU7200"]],[["td","Electronic pressure monitor, PN7594"]],[["td","filter"]],[["td","water stop valve"]],[["td","regulating valve"]],[["td","backstop"]],[["td","Cover plate"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangssignal","keyOrName":"at_ausgangssignal","name":"Output signal","tableValue":null,"type":"string","uom":"","value":"switching signal","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgangsfunktion-digital","keyOrName":"at_ausgangsfunktion-digital","name":"Output function","tableValue":null,"type":"string","uom":"","value":"normally open / closed;  (configurable)","valueList":null}],"name":""}],"sectionName":"Outputs"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_druck-messbereich-bar-bereich","keyOrName":"at_druck-messbereich-bar-bereich","name":"Measuring range","tableValue":null,"type":"string","uom":"[bar]","value":"0...10","valueList":null}],"name":"Pressure monitoring"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_stroemung-messbereich-lpmin-bereich","keyOrName":"at_stroemung-messbereich-lpmin-bereich","name":"Measuring range","tableValue":null,"type":"string","uom":"[l/min]","value":"0...50","valueList":null}],"name":"Flow monitoring"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messbereich-cel-bereich","keyOrName":"at_temperatur-messbereich-cel-bereich","name":"Measuring range","tableValue":null,"type":"string","uom":"[°C]","value":"-10...80","valueList":null}],"name":"Temperature monitoring"}],"sectionName":"Measuring/setting range"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-10...50","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_lagertemperatur-cel-bereich","keyOrName":"at_lagertemperatur-cel-bereich","name":"Storage temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 65;  (sensors)","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_emv","keyOrName":"at_emv","name":"EMC","tableValue":[[["td","DIN EN 61000-6-2"],["td",""]],[["td","DIN EN 61000-6-3"],["td",""]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_druckgeraeterichtlinie","keyOrName":"at_druckgeraeterichtlinie","name":"Pressure equipment directive","tableValue":null,"type":"string","uom":"","value":"sound engineering practice; can be used for group 2 fluids; group 1 fluids on request","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"7781.2","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_montageart","keyOrName":"at_montageart","name":"Type of mounting","tableValue":null,"type":"string","uom":"","value":"mounting bracket with protective cover","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"500 x 218 x 150","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; PBT+PC-GF30; bronze (2.1096.01); Aluminum Alloy anodized AlMgSi0,5; PA","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoff-in-mediumkontakt-text","keyOrName":"at_werkstoff-in-mediumkontakt-text","name":"Materials (wetted parts)","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L); FKM; PES; NBR; PVDF; Centellen 200; ceramics","valueList":null}],"name":""},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"threaded connection M22 x 1,5 external thread","valueList":null}],"name":"Process connection for welding gun"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"threaded connection M22 x 1,5 external thread","valueList":null}],"name":"Process connection for water supply"}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"plug connection","keyOrName":"plug connection","name":"Connector","tableValue":null,"type":"String","uom":"","value":"3 x M12; Contacts: gold-plated","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[{"text":"Article to be discontinued <br/>Discontinuation date: 12/31/2025 ","type":"info"}],"lastModified":"Tue Apr 07 23:25:20 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[[["td","1"],["td","filter"]],[["td","2"],["td","Flow sensor"]],[["td","3"],["td","water stop valve"]],[["td","4"],["td","backstop"]],[["td","5"],["td","regulating valve"]],[["td","6"],["td","pressure sensor"]],[["td","7"],["td","Cover plate"]]],"scaleDrawingRef":"https://media.ifm.com/dam/9c3d61ba-1728-4e1b-a1d3-b39f8c5f5479/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0070.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/1bad7670-0dad-47a2-a156-e9cd01844252/Original/ZZ0057-01_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/9c3d61ba-1728-4e1b-a1d3-b39f8c5f5479/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0070.png"}