{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — TS4759-00 — 19.01.2026","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/78575100-42f3-408a-8402-40ad80b4a452/Original/AN_I_1019.jpg","connectionImageCaption":[[["td",""],["td","Core colors :"]],[["td","RD ="],["td","red"]],[["td","WH ="],["td","white"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"connectionDescriptionAttachable":"","connectionDescriptionCable":"Cable: 4 m, silicone, Ø 5 mm; with wire end ferrules; 4 x 0.34 mm²","connectionDescriptionPlug":"","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/78575100-42f3-408a-8402-40ad80b4a452/Original/AN_I_1019.jpg","connectionImageCaption":[[["td",""],["td","Core colors :"]],[["td","RD ="],["td","red"]],[["td","WH ="],["td","white"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"pinLayoutImage":"","pinLayoutImageDesc":"","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messbereich-generictable","keyOrName":"at_temperatur-messbereich-generictable","name":"Measuring range","tableValue":[[["td","-30...180 °C"],["td","-22...356 °F"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"threaded connection M5 external thread","valueList":null}],"name":""}],"sectionName":"Product characteristics"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messelement","keyOrName":"at_temperatur-messelement","name":"Measuring element","tableValue":null,"type":"string","uom":"","value":"1 x Pt 100;  (to DIN EN 60751, class A)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-montage","keyOrName":"at_einsatzbereich-montage","name":"Installation","tableValue":null,"type":"string","uom":"","value":"Contact sensor for solid bodies","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzklasse","keyOrName":"at_schutzklasse","name":"Protection class","tableValue":null,"type":"string","uom":"","value":"III","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messbereich-generictable","keyOrName":"at_temperatur-messbereich-generictable","name":"Measuring range","tableValue":[[["td","-30...180 °C"],["td","-22...356 °F"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Measuring/setting range"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_genauigkeit-k","keyOrName":"at_genauigkeit-k","name":"Accuracy","tableValue":null,"type":"string","uom":"[K]","value":"± (0,15 K + 0,002 x|t|)","valueList":null}],"name":""}],"sectionName":"Accuracy / deviations"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-ansprechdynamik","keyOrName":"at_temperatur-ansprechdynamik","name":"Dynamic response T05 / T09","tableValue":null,"type":"string","uom":"[s]","value":"3 / 8;  (according to DIN EN 60751)","valueList":null}],"name":""}],"sectionName":"Reaction times"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 67","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"12684","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"159.6","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"tubular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-sensorbauform","keyOrName":"at_temperatur-sensorbauform","name":"Design","tableValue":null,"type":"string","uom":"","value":"screw-in sensor","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"threaded connection M5 external thread","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stabdurchmesser","keyOrName":"at_stabdurchmesser","name":"Probe diameter","tableValue":null,"type":"decimal","uom":"[mm]","value":"4","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"cable connection","keyOrName":"cable connection","name":"Cable","tableValue":null,"type":"String","uom":"","value":"4 m, silicone, Ø 5 mm; with wire end ferrules; 4 x 0.34 mm²","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Fri Aug 14 18:04:59 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[],"scaleDrawingRef":"https://media.ifm.com/dam/9650ade9-f824-48c3-af77-490030d844d2/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_600_0038.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/2e9270df-4037-494b-9957-973b7e314d5e/Original/TS4759-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/9650ade9-f824-48c3-af77-490030d844d2/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_600_0038.png"}