{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ex":"/responsive/original/content/gallery/productcertificates/ex.png?v=2092870221"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — EN-US — TS325A — 24.07.2025","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/2d53e6d9-6ba5-468a-b42f-08deba8b2a8f/Original/AN_I_0503.jpg","connectionImageCaption":[[["td","1 ="],["td","screen not connected to the housing"]],[["td",""],["td","Core colors :"]],[["td","WH ="],["td","white"]],[["td","BK ="],["td","black"]],[["td","RD ="],["td","red"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"connectionDescriptionAttachable":"","connectionDescriptionCable":"Cable: 3 m, silicone, screened","connectionDescriptionPlug":"","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/2d53e6d9-6ba5-468a-b42f-08deba8b2a8f/Original/AN_I_0503.jpg","connectionImageCaption":[[["td","1 ="],["td","screen not connected to the housing"]],[["td",""],["td","Core colors :"]],[["td","WH ="],["td","white"]],[["td","BK ="],["td","black"]],[["td","RD ="],["td","red"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"pinLayoutImage":"","pinLayoutImageDesc":"","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messbereich-generictable","keyOrName":"at_temperatur-messbereich-generictable","name":"Measuring range","tableValue":[[["td","-20...80 °C"],["td","-4...176 °F"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"Clamp fitting Ø 5 mm","valueList":null}],"name":""}],"sectionName":"Product characteristics"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_besondere-eigenschaft","keyOrName":"at_besondere-eigenschaft","name":"Special feature","tableValue":null,"type":"string","uom":"","value":"screened cable","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messelement","keyOrName":"at_temperatur-messelement","name":"Measuring element","tableValue":null,"type":"string","uom":"","value":"1 x Pt 100;  (to DIN EN 60751, class B; operating current max. 10 mA)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_medien-tag","keyOrName":"at_medien-tag","name":"Media","tableValue":null,"type":"string","uom":"","value":"liquids and gases","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mindesteintauchtiefe","keyOrName":"at_mindesteintauchtiefe","name":"Minimum installation depth","tableValue":null,"type":"decimal","uom":"[mm]","value":"15","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_isolationsfestigkeit","keyOrName":"at_isolationsfestigkeit","name":"Insulation rating","tableValue":null,"type":"string","uom":"[V]","value":"2500;  (Insulation between sensor housing and internal)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzklasse","keyOrName":"at_schutzklasse","name":"Protection class","tableValue":null,"type":"string","uom":"","value":"III","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messbereich-generictable","keyOrName":"at_temperatur-messbereich-generictable","name":"Measuring range","tableValue":[[["td","-20...80 °C"],["td","-4...176 °F"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-messbereich-zusatz","keyOrName":"at_temperatur-messbereich-zusatz","name":"Note on measuring range","tableValue":[[["td","Measuring range for non-ATEX applications: -20...180 °C / -4...356 °F"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Measuring/setting range"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_genauigkeit-k","keyOrName":"at_genauigkeit-k","name":"Accuracy","tableValue":null,"type":"string","uom":"[K]","value":"± (0,30 K + 0,005 x|t|)","valueList":null}],"name":""}],"sectionName":"Accuracy / deviations"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperatur-ansprechdynamik","keyOrName":"at_temperatur-ansprechdynamik","name":"Dynamic response T05 / T09","tableValue":null,"type":"string","uom":"[s]","value":"4 / 10;  (according to DIN EN 60751)","valueList":null}],"name":""}],"sectionName":"Reaction times"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-20...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 67","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"suppliers/ifm/documents/inlineimages/Ex.png","inlineImageUrl":"/restservices/us/en/assets/c3VwcGxpZXJzL2lmbS9kb2N1bWVudHMvaW5saW5laW1hZ2VzL0V4LnBuZw==","key":"at_atex-kennzeichnung","keyOrName":"at_atex-kennzeichnung","name":"ATEX marking","tableValue":null,"type":"string","uom":"","value":"II 3D Ex tc IIIC T100°C Dc X","valueList":null},{"inlineImage":"suppliers/ifm/documents/inlineimages/Ex.png","inlineImageUrl":"/restservices/us/en/assets/c3VwcGxpZXJzL2lmbS9kb2N1bWVudHMvaW5saW5laW1hZ2VzL0V4LnBuZw==","key":"at_atex-kennzeichnung","keyOrName":"at_atex-kennzeichnung","name":"","tableValue":null,"type":"string","uom":"","value":"II 3G Ex ec IIC T5 Gc X","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"19026","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"88.6","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"tubular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"Ø 5 / L = 40","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoff-in-mediumkontakt-text","keyOrName":"at_werkstoff-in-mediumkontakt-text","name":"Materials (wetted parts)","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"Clamp fitting Ø 5 mm","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stabdurchmesser","keyOrName":"at_stabdurchmesser","name":"Probe diameter","tableValue":null,"type":"decimal","uom":"[mm]","value":"5","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_bemerkungen","keyOrName":"at_bemerkungen","name":"Remarks","tableValue":[[["td"," The values for accuracy apply to flowing water."]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"cable connection","keyOrName":"cable connection","name":"Cable","tableValue":null,"type":"String","uom":"","value":"3 m, silicone, screened","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"","freeTableSection":null,"infoBox":[],"lastModified":"Thu Aug 13 07:40:54 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[],"scaleDrawingRef":"https://media.ifm.com/dam/97a74088-94d3-47d4-8131-e72226b9ad40/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_600_0051.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/3c742bde-db14-4afe-ba33-39622e8aa8f0/Original/TS325A-03_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/97a74088-94d3-47d4-8131-e72226b9ad40/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_600_0051.png"}