{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300","cul":"/responsive/original/content/gallery/productcertificates/cul.png?v=-2057296668"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SR5906-02 — 11.10.2024","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[],"connectionDescriptionAttachable":"","connectionDescriptionCable":"","connectionDescriptionPlug":"Connector: 1 x 1/2\"; coding: C; Contacts: 5","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/f1590dfd-fbcd-46c9-9087-eff97ccf00bc/Original/AN_I_0117.jpg","connectionImageCaption":[[["td","n.c. ="],["td","not used"]],[["td","Note"],["td","miniature fuse to IEC60127-2 sheet 1 ≤ 5 A fast acting"]],[["td","Caution"],["td","no protective insulation between relay circuit and supply voltage"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"pin"}],"pinLayoutImage":"https://media.ifm.com/dam/eba36d31-9910-4a8a-80a9-bee20735483a/pim,w_0.6;r_pad,w_1.02,h_1.02,bc_white/PIN_0093.png","pinLayoutImageDesc":"Connector: 1 x 1/2\"; coding: C; Contacts: 5","pinLayoutImageUrl":null,"pinSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/f1590dfd-fbcd-46c9-9087-eff97ccf00bc/Original/AN_I_0117.jpg","connectionImageCaption":[[["td","n.c. ="],["td","not used"]],[["td","Note"],["td","miniature fuse to IEC60127-2 sheet 1 ≤ 5 A fast acting"]],[["td","Caution"],["td","no protective insulation between relay circuit and supply voltage"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"pin"}],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"Flow monitoring; Wire break monitoring","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung-ac-frequenz-bereich","keyOrName":"at_betriebsspannung-ac-frequenz-bereich","name":"Frequency AC","tableValue":null,"type":"string","uom":"[Hz]","value":"47...63","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung-toleranz-prozent","keyOrName":"at_betriebsspannung-toleranz-prozent","name":"Operating voltage tolerance","tableValue":null,"type":"string","uom":"[%]","value":"-15...10","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung","keyOrName":"at_betriebsspannung","name":"Operating voltage","tableValue":null,"type":"string","uom":"[V]","value":"90...240 AC","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_max-leistungsaufnahme-schein","keyOrName":"at_max-leistungsaufnahme-schein","name":"Max. power consumption","tableValue":null,"type":"decimal","uom":"[VA]","value":"3.5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzklasse","keyOrName":"at_schutzklasse","name":"Protection class","tableValue":null,"type":"string","uom":"","value":"II","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpolungsfest","keyOrName":"at_verpolungsfest","name":"Reverse polarity protection","tableValue":null,"type":"string","uom":"","value":"no","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_bereitschaftsverz-zeit","keyOrName":"at_bereitschaftsverz-zeit","name":"Power-on delay time","tableValue":null,"type":"string","uom":"[s]","value":"10","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_anzahl-kanaele","keyOrName":"at_anzahl-kanaele","name":"Number of channels","tableValue":null,"type":"integer","uom":"","value":"1","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-ausfuehrung","keyOrName":"at_elektrische-ausfuehrung","name":"Electrical design","tableValue":null,"type":"string","uom":"","value":"Relay","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_kontaktbelastbarkeit","keyOrName":"at_kontaktbelastbarkeit","name":"Contact rating","tableValue":null,"type":"string","uom":"","value":"3 A (250 V AC / 30 V DC);  (switching cycles at 3 A load: 100.000; type of switch-off: normally open)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltspiele-mechanisch","keyOrName":"at_schaltspiele-mechanisch","name":"Switching cycles (mechanical)","tableValue":null,"type":"string","uom":"","value":"20_Millionen","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltfunktion-ueberwachung-stroemung","keyOrName":"at_schaltfunktion-ueberwachung-stroemung","name":"Switching function flow monitoring","tableValue":null,"type":"string","uom":"","value":"output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-kurzschlussschutz","keyOrName":"at_ausgaenge-kurzschlussschutz","name":"Short-circuit protection","tableValue":null,"type":"string","uom":"","value":"no","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-ueberlastfest","keyOrName":"at_ausgaenge-ueberlastfest","name":"Overload protection","tableValue":null,"type":"string","uom":"","value":"no","valueList":null}],"name":""}],"sectionName":"Outputs"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltpunktabgleich-stroemung","keyOrName":"at_schaltpunktabgleich-stroemung","name":"Adjustment of the switch point","tableValue":null,"type":"string","uom":"","value":"pushbuttons","valueList":null}],"name":""}],"sectionName":"Software / programming"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-20...60","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 67;  (with sensor attached)","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_emv","keyOrName":"at_emv","name":"EMC","tableValue":[[["td","EN 61000-4-2 ESD"],["td","4 kV CD / 8 kV AD"]],[["td","EN 61000-4-3 HF radiated"],["td","10 V/m"]],[["td","EN 61000-4-4 Burst"],["td","2 kV"]],[["td","EN 61000-4-6 HF conducted"],["td","10 V"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schockfestigkeit","keyOrName":"at_schockfestigkeit","name":"Shock resistance","tableValue":[[["td","DIN IEC 68-2-27"],["td","30 g (6 ms)"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_vibrationsfestigkeit","keyOrName":"at_vibrationsfestigkeit","name":"Vibration resistance","tableValue":[[["td","DIN IEC 68-2-6"],["td","2 g (55...2000 Hz)"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"209","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"244.5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"tubular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"Ø 50 / L = 83","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_anzeige","keyOrName":"at_anzeige","name":"Display","tableValue":[[["td","Function"],["td","LED, bar graph"]],[["td","Switching status"],["td","LED, orange flash in case of wire break"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Displays / operating elements"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erforderliche-absicherung","keyOrName":"at_erforderliche-absicherung","name":"Required protection","tableValue":null,"type":"string","uom":"","value":"miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting","valueList":null}],"name":""}],"sectionName":"Electrical connection"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_bemerkungen","keyOrName":"at_bemerkungen","name":"Remarks","tableValue":[[["td"," connection for flow sensor without short-circuit protection / reverse polarity protection"]],[["td"," The flow sensor must be directly connected to the control monitor."]],[["td"," A connection by means of extension cables is not allowed."]],[["td","Recommendation Check the safe functioning of the unit after a short circuit."]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"plug connection","keyOrName":"plug connection","name":"Connector","tableValue":null,"type":"String","uom":"","value":"1 x 1/2\"; coding: C; Contacts: 5","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Sat Aug 15 12:25:50 CEST 2026","madeInRemark":"","scaleDrawingLegend":[[["td","1"],["td","LED display"]],[["td","2"],["td","setting pushbutton"]],[["td","3"],["td","connection for voltage supply and output signals"]],[["td","4"],["td","connection for flow sensor"]]],"scaleDrawingRef":"https://media.ifm.com/dam/5b243c9a-1c30-4e06-bef4-a6a3dca9dc61/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0117.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/87fd7b25-5d4d-443a-b0b1-d2b48019fa53/Original/SR5906-02_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/5b243c9a-1c30-4e06-bef4-a6a3dca9dc61/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0117.png"}