{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300","ex":"/responsive/original/content/gallery/productcertificates/ex.png?v=2092870221","iec":"/responsive/original/content/gallery/productcertificates/iec.png?v=-2057280840"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — EN-US — SR307A — 06.04.2023","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/b4cec6a5-8bf6-4b33-9457-9db08bf1e810/Original/AN_I_1246_GG.jpg","connectionImageCaption":[[["td","1"],["td","Flow monitoring"]],[["td","2"],["td","Fault monitoring"]],[["td","3"],["td","Temperature monitoring"]],[["td","Note"],["td","miniature fuse to IEC60127-2 sheet 1 ≤ 5 A fast acting"]],[["td",""],["td","Place the fuse outside the hazardous area."]],[["td",""],["td","Core colors :"]],[["td","BK ="],["td","black"]],[["td","BN ="],["td","brown"]],[["td","BU ="],["td","blue"]],[["td","WH ="],["td","white"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"connectionDescriptionAttachable":"terminals: 15 x ...2.5 mm²","connectionDescriptionCable":"","connectionDescriptionPlug":"","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/b4cec6a5-8bf6-4b33-9457-9db08bf1e810/Original/AN_I_1246_GG.jpg","connectionImageCaption":[[["td","1"],["td","Flow monitoring"]],[["td","2"],["td","Fault monitoring"]],[["td","3"],["td","Temperature monitoring"]],[["td","Note"],["td","miniature fuse to IEC60127-2 sheet 1 ≤ 5 A fast acting"]],[["td",""],["td","Place the fuse outside the hazardous area."]],[["td",""],["td","Core colors :"]],[["td","BK ="],["td","black"]],[["td","BN ="],["td","brown"]],[["td","BU ="],["td","blue"]],[["td","WH ="],["td","white"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"beschaltung"}],"pinLayoutImage":"","pinLayoutImageDesc":"","pinLayoutImageUrl":null,"pinSubSections":[],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ausfuehrung","keyOrName":"at_ausfuehrung","name":"Design","tableValue":null,"type":"string","uom":"","value":"housing for DIN rail mounting","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"Flow monitoring; Temperature monitoring; Wire break monitoring","valueList":null}],"name":""}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung-toleranz-prozent","keyOrName":"at_betriebsspannung-toleranz-prozent","name":"Operating voltage tolerance","tableValue":null,"type":"string","uom":"[%]","value":"-15...15","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_betriebsspannung","keyOrName":"at_betriebsspannung","name":"Operating voltage","tableValue":null,"type":"string","uom":"[V]","value":"24 DC","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stromaufnahme","keyOrName":"at_stromaufnahme","name":"Current consumption","tableValue":null,"type":"string","uom":"[mA]","value":"100","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpolungsfest","keyOrName":"at_verpolungsfest","name":"Reverse polarity protection","tableValue":null,"type":"string","uom":"","value":"no","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_bereitschaftsverz-zeit","keyOrName":"at_bereitschaftsverz-zeit","name":"Power-on delay time","tableValue":null,"type":"string","uom":"[s]","value":"10","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_anzahl-kanaele","keyOrName":"at_anzahl-kanaele","name":"Number of channels","tableValue":null,"type":"integer","uom":"","value":"1","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verhalten-im-fehlerfall","keyOrName":"at_verhalten-im-fehlerfall","name":"Performance in case of a fault","tableValue":null,"type":"string","uom":"","value":"Relay de-energized in case of the following faults: wire break, reverse polarity or short circuit of the sensor cable, undervoltage, internal fault","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_elektrische-ausfuehrung","keyOrName":"at_elektrische-ausfuehrung","name":"Electrical design","tableValue":null,"type":"string","uom":"","value":"Relay","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_kontaktbelastbarkeit","keyOrName":"at_kontaktbelastbarkeit","name":"Contact rating","tableValue":null,"type":"string","uom":"","value":"4 A (250 V AC cos phi > 0,7) ; 0,2 A (250 V DC); 4 A (24 V DC)","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltfunktion-ueberwachung-stroemung","keyOrName":"at_schaltfunktion-ueberwachung-stroemung","name":"Switching function flow monitoring","tableValue":null,"type":"string","uom":"","value":"relay energized when flow is present","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltfunktion-ueberwachung-temperatur","keyOrName":"at_schaltfunktion-ueberwachung-temperatur","name":"Switching function temperature monitoring","tableValue":null,"type":"string","uom":"","value":"relay de-energized when temperature is exceeded","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-kurzschlussfest","keyOrName":"at_ausgaenge-kurzschlussfest","name":"Short-circuit proof","tableValue":null,"type":"string","uom":"","value":"no","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_ausgaenge-ueberlastfest","keyOrName":"at_ausgaenge-ueberlastfest","name":"Overload protection","tableValue":null,"type":"string","uom":"","value":"no","valueList":null}],"name":""}],"sectionName":"Outputs"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_schaltpunktabgleich-stroemung","keyOrName":"at_schaltpunktabgleich-stroemung","name":"Adjustment of the switch point","tableValue":null,"type":"string","uom":"","value":"Programming buttons","valueList":null}],"name":""}],"sectionName":"Software / programming"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_umgebungstemperatur-cel-bereich","keyOrName":"at_umgebungstemperatur-cel-bereich","name":"Ambient temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-20...60","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_lagertemperatur-cel-bereich","keyOrName":"at_lagertemperatur-cel-bereich","name":"Storage temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 20","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart-klemmen-wert","keyOrName":"at_schutzart-klemmen-wert","name":"Protection rating terminals","tableValue":null,"type":"string","uom":"","value":"IP 20","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_zulassungen","keyOrName":"at_zulassungen","name":"Approval","tableValue":null,"type":"string","uom":"","value":"CSANe 21ATEX2238; IECEx CSA 21.0044","valueList":null},{"inlineImage":"suppliers/ifm/documents/inlineimages/Ex.png","inlineImageUrl":"/restservices/us/en/assets/c3VwcGxpZXJzL2lmbS9kb2N1bWVudHMvaW5saW5laW1hZ2VzL0V4LnBuZw==","key":"at_atex-kennzeichnung","keyOrName":"at_atex-kennzeichnung","name":"ATEX marking","tableValue":null,"type":"string","uom":"","value":"II (1) G [Ex ia Ga] IIC","valueList":null},{"inlineImage":"suppliers/ifm/documents/inlineimages/Ex.png","inlineImageUrl":"/restservices/us/en/assets/c3VwcGxpZXJzL2lmbS9kb2N1bWVudHMvaW5saW5laW1hZ2VzL0V4LnBuZw==","key":"at_atex-kennzeichnung","keyOrName":"at_atex-kennzeichnung","name":"","tableValue":null,"type":"string","uom":"","value":"II (1) G [Ex ia Ga] IIB","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"124","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"368","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"rectangular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_montageart","keyOrName":"at_montageart","name":"Type of mounting","tableValue":null,"type":"string","uom":"","value":"Mounting on DIN rail;  (TH35 (EN 60715))","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"104.5 x 32.5 x 113.6","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"PA","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_anzeige","keyOrName":"at_anzeige","name":"Display","tableValue":[[["td","fault"],["td","LED, red"]],[["td","Function"],["td","LED, bar graph"]],[["td","Switching status"],["td","LED, yellow"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Displays / operating elements"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erforderliche-absicherung","keyOrName":"at_erforderliche-absicherung","name":"Required protection","tableValue":null,"type":"string","uom":"","value":"miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting; Place the fuse outside the hazardous area.","valueList":null}],"name":""}],"sectionName":"Electrical connection"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_bemerkungen","keyOrName":"at_bemerkungen","name":"Remarks","tableValue":[[["td","Caution The control monitor must be mounted outside the hazardous area."]],[["td","Recommendation Check the safe functioning of the unit after a short circuit."]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"attachable connection","keyOrName":"attachable connection","name":"terminals","tableValue":null,"type":"String","uom":"","value":"15 x ...2.5 mm²","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"","freeTableSection":{"freeTableList":[{"body":"\n<table>\n<tr>\n<td>in protection rating intrinsic safety</td>\n<td>[Ex ia Ga] IIC</td>\n<td>[Ex ia Ga] IIB</td>\n<td>[Ex ib Gb] IIC</td>\n<td>[Ex ib Gb] IIB</td>\n</tr>\n<tr>\n<td>Voltage [V]</td>\n<td>9.6</td>\n<td>9.6</td>\n<td>9.6</td>\n<td>9.6</td>\n</tr>\n<tr>\n<td>Current [mA]</td>\n<td>332</td>\n<td>332</td>\n<td>332</td>\n<td>332</td>\n</tr>\n<tr>\n<td>Power [mW]</td>\n<td>531</td>\n<td>531</td>\n<td>531</td>\n<td>531</td>\n</tr>\n<tr>\n<td>External inductance [mH]</td>\n<td>0.3</td>\n<td>1.2</td>\n<td>0.3</td>\n<td>1.2</td>\n</tr>\n<tr>\n<td>External capacitance [µF]</td>\n<td>3.15</td>\n<td>25.55</td>\n<td>3.15</td>\n<td>25.55</td>\n</tr>\n</table>\n\n","footer":null,"header":"Maximum values for control circuit"}],"sectionName":"Other data"},"infoBox":[{"text":"Article to be discontinued <br/>Discontinuation date: 03/31/2026 ","type":"info"}],"lastModified":"Thu Apr 09 01:30:04 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[[["td","1"],["td","LED display"]],[["td","2"],["td","setting pushbuttons"]]],"scaleDrawingRef":"https://media.ifm.com/dam/e770147d-b878-40c4-8791-50c7cd4ab3be/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0158.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/7229c965-c6dd-439c-bee5-500221c9c740/Original/SR307A-01_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/e770147d-b878-40c4-8791-50c7cd4ab3be/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0158.png"}