{"datasheetResultDocument":{"certificateImages":{"ce":"/responsive/original/content/gallery/productcertificates/ce.png?v=-2057297231","ukca":"/responsive/original/content/gallery/productcertificates/ukca.png?v=-1942099300","reg31":"/responsive/original/content/gallery/productcertificates/reg31.png?v=-2057279528","cul":"/responsive/original/content/gallery/productcertificates/cul.png?v=-2057296668"},"completeFooter":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SF6201-00 — 05.11.2020","connections":[{"anschlussbelegungSubSections":[],"beschaltungSubSections":[],"connectionDescriptionAttachable":"","connectionDescriptionCable":"","connectionDescriptionPlug":"Connector: 1 x M12; coding: A; Contacts: 5, gold-plated; Maximum cable length: 100 m","connectionSubSectionList":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/e97b7fc5-ab82-494c-97bd-674585244cc5/Original/AN_I_0120.jpg","connectionImageCaption":[[["td",""],["td","Core colors :"]],[["td","BN ="],["td","brown"]],[["td","BU ="],["td","blue"]],[["td","BK ="],["td","black"]],[["td","WH ="],["td","white"]],[["td","GY ="],["td","grey"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"pin"}],"pinLayoutImage":"https://media.ifm.com/dam/20f6da2a-1c3b-48c8-88cc-511666400fce/pim,w_0.6;r_pad,w_1.02,h_1.02,bc_white/PIN_0063.png","pinLayoutImageDesc":"Connector: 1 x M12; coding: A; Contacts: 5, gold-plated; Maximum cable length: 100 m","pinLayoutImageUrl":null,"pinSubSections":[{"connectionHeading":"","connectionImage":"https://media.ifm.com/dam/e97b7fc5-ab82-494c-97bd-674585244cc5/Original/AN_I_0120.jpg","connectionImageCaption":[[["td",""],["td","Core colors :"]],[["td","BN ="],["td","brown"]],[["td","BU ="],["td","blue"]],[["td","BK ="],["td","black"]],[["td","WH ="],["td","white"]],[["td","GY ="],["td","grey"]]],"connectionImageUrl":null,"footerText":[],"pinAssignment":[],"subsectionName":"Connection","type":"pin"}],"sectionName":"Electrical connection"}],"datasheetSections":[{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_stablaenge","keyOrName":"at_stablaenge","name":"Probe length L","tableValue":null,"type":"string","uom":"[mm]","value":"15...107","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"Clamp fitting Ø 10 mm","valueList":null}],"name":""}],"sectionName":"Product characteristics"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_besondere-eigenschaft","keyOrName":"at_besondere-eigenschaft","name":"Special feature","tableValue":null,"type":"string","uom":"","value":"gold-plated contacts","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"high temperature","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-montage","keyOrName":"at_einsatzbereich-montage","name":"Installation","tableValue":null,"type":"string","uom":"","value":"Sensor suitable for clamp fitting","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_medien-tag","keyOrName":"at_medien-tag","name":"Media","tableValue":null,"type":"string","uom":"","value":"Liquids; Gases","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mediumtemp-cel","keyOrName":"at_mediumtemp-cel","name":"Medium temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_druckfestigkeit-generictable","keyOrName":"at_druckfestigkeit-generictable","name":"Pressure rating","tableValue":[[["td","30 bar"],["td","3 MPa"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-applikation","keyOrName":"at_einsatzbereich-applikation","name":"Application","tableValue":null,"type":"string","uom":"","value":"high temperature","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_einsatzbereich-montage","keyOrName":"at_einsatzbereich-montage","name":"Installation","tableValue":null,"type":"string","uom":"","value":"Sensor suitable for clamp fitting","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mediumtemp-cel","keyOrName":"at_mediumtemp-cel","name":"Medium temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null}],"name":"Liquids"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_mediumtemp-cel","keyOrName":"at_mediumtemp-cel","name":"Medium temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null}],"name":"Gases"}],"sectionName":"Application"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_anschluss-an-auswerteelektronik","keyOrName":"at_anschluss-an-auswerteelektronik","name":"Connection to control monitor","tableValue":null,"type":"string","uom":"","value":"VS3000","valueList":null}],"name":""}],"sectionName":"Electrical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_stablaenge","keyOrName":"at_stablaenge","name":"Probe length L","tableValue":null,"type":"string","uom":"[mm]","value":"15...107","valueList":null}],"name":""},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_stroemung-einstellbereich-cmps-bereich","keyOrName":"at_stroemung-einstellbereich-cmps-bereich","name":"Setting range","tableValue":null,"type":"string","uom":"[cm/s]","value":"3...300","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stroemung-groesste-empfindlichk-cmps-bereich","keyOrName":"at_stroemung-groesste-empfindlichk-cmps-bereich","name":"Greatest sensitivity","tableValue":null,"type":"string","uom":"[cm/s]","value":"3...60","valueList":null}],"name":"Liquids"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_stroemung-einstellbereich-cmps-bereich","keyOrName":"at_stroemung-einstellbereich-cmps-bereich","name":"Setting range","tableValue":null,"type":"string","uom":"[cm/s]","value":"200...3000","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stroemung-groesste-empfindlichk-cmps-bereich","keyOrName":"at_stroemung-groesste-empfindlichk-cmps-bereich","name":"Greatest sensitivity","tableValue":null,"type":"string","uom":"[cm/s]","value":"200...800","valueList":null}],"name":"Gases"}],"sectionName":"Measuring/setting range"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_temperaturgradient","keyOrName":"at_temperaturgradient","name":"Max. temperature gradient of medium","tableValue":null,"type":"decimal","uom":"[K/min]","value":"30","valueList":null}],"name":""}],"sectionName":"Accuracy / deviations"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ansprechzeit-s","keyOrName":"at_ansprechzeit-s","name":"Response time","tableValue":null,"type":"string","uom":"[s]","value":"1...10","valueList":null}],"name":""},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ansprechzeit-s","keyOrName":"at_ansprechzeit-s","name":"Response time","tableValue":null,"type":"string","uom":"[s]","value":"1...10","valueList":null}],"name":"Liquids"},{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_ansprechzeit-s","keyOrName":"at_ansprechzeit-s","name":"Response time","tableValue":null,"type":"string","uom":"[s]","value":"1...10","valueList":null}],"name":"Gases"}],"sectionName":"Reaction times"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_lagertemperatur-cel-bereich","keyOrName":"at_lagertemperatur-cel-bereich","name":"Storage temperature","tableValue":null,"type":"string","uom":"[°C]","value":"-25...80","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_schutzart","keyOrName":"at_schutzart","name":"Protection","tableValue":null,"type":"string","uom":"","value":"IP 67","valueList":null}],"name":""}],"sectionName":"Operating conditions"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_schockfestigkeit","keyOrName":"at_schockfestigkeit","name":"Shock resistance","tableValue":[[["td","DIN IEC 68-2-27"],["td","40 g (11 ms)"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_vibrationsfestigkeit","keyOrName":"at_vibrationsfestigkeit","name":"Vibration resistance","tableValue":[[["td","DIN IEC 68-2-6"],["td","10 g (55...2000 Hz)"]]],"type":"text-table","uom":"","value":null,"valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_mttf","keyOrName":"at_mttf","name":"MTTF","tableValue":null,"type":"decimal","uom":"[years]","value":"8394","valueList":null}],"name":""}],"sectionName":"Tests / approvals"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_erp-bruttogewicht-wert","keyOrName":"at_erp-bruttogewicht-wert","name":"Weight","tableValue":null,"type":"decimal","uom":"[g]","value":"62.5","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_gehaeuse","keyOrName":"at_gehaeuse","name":"Housing","tableValue":null,"type":"string","uom":"","value":"tubular","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_dimensions","keyOrName":"at_dimensions","name":"Dimensions","tableValue":null,"type":"string","uom":"[mm]","value":"Ø 10 / L = 132","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoffe-gehaeuse-text","keyOrName":"at_werkstoffe-gehaeuse-text","name":"Material","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L) several parts, welded","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_werkstoff-in-mediumkontakt-text","keyOrName":"at_werkstoff-in-mediumkontakt-text","name":"Materials (wetted parts)","tableValue":null,"type":"string","uom":"","value":"stainless steel (1.4404 / 316L) several parts, welded","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_prozessanschluss","keyOrName":"at_prozessanschluss","name":"Process connection","tableValue":null,"type":"string","uom":"","value":"Clamp fitting Ø 10 mm","valueList":null},{"inlineImage":"","inlineImageUrl":null,"key":"at_stabdurchmesser","keyOrName":"at_stabdurchmesser","name":"Probe diameter","tableValue":null,"type":"decimal","uom":"[mm]","value":"7.7","valueList":null}],"name":""}],"sectionName":"Mechanical data"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_zubehoer-optional","keyOrName":"at_zubehoer-optional","name":"Accessories (optional)","tableValue":[[["td","Clamp adapter: R 1/2, E40160"]],[["td","Clamp adapter: 1/2\" NPT, E40174"]]],"type":"text-table","uom":"","value":null,"valueList":null}],"name":""}],"sectionName":"Accessories"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":"","inlineImageUrl":null,"key":"at_verpackungseinheit","keyOrName":"at_verpackungseinheit","name":"Pack quantity","tableValue":null,"type":"string","uom":"","value":"1 pcs.","valueList":null}],"name":""}],"sectionName":"Remarks"},{"datasheetSubSectionList":[{"dataSheetAttributesList":[{"inlineImage":null,"inlineImageUrl":null,"key":"plug connection","keyOrName":"plug connection","name":"Connector","tableValue":null,"type":"String","uom":"","value":"1 x M12; coding: A; Contacts: 5, gold-plated; Maximum cable length: 100 m","valueList":null}],"name":null}],"sectionName":"Electrical connection"}],"diagramSections":[],"footerAddress":"ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355","footerDate":null,"footerRemark":"We reserve the right to make technical alterations without prior notice.","freeTableSection":null,"infoBox":[],"lastModified":"Sat Aug 15 17:46:25 CEST 2026","madeInRemark":"Made in Germany","scaleDrawingLegend":[],"scaleDrawingRef":"https://media.ifm.com/dam/ba076ea6-7569-4654-9a08-b6f960b9f7d5/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0166.png"},"defaultPdfDatasheetUrl":"https://media.ifm.com/dam/db48974b-ec93-4bbe-81d1-c287ede36491/Original/SF6201-00_EN-US.pdf","scaleDrawingUrl":"https://media.ifm.com/dam/ba076ea6-7569-4654-9a08-b6f960b9f7d5/pim,w_0.9;r_pad,w_2000,h_1.01,bc_white/P_MZ_300_0166.png"}